Every station is worked out now by VERA’s own code: the order, the analyser’s message, the read-only copy, the checks, the approvals and the person’s own record. It takes a few seconds.
Loading the sample journey.
Sample journey
Mariam's sample, station by station
Sample run through VERA's pipeline
Eleven stations, from the tube to the person's own record. Each one shows what VERA’s own code did at that step to this sample, in the run below.
Mariam on the Sysmex urine line
Released
Urine test (chemistry, cells, images)
Tube IRN261129033
Urine
Run at 17:27 GST
VERA worked this run out at 17:27 GST, in 253 ms of its own code, and keeps it up to 30 minutes in memory for anyone who opens the same run
VERA ran this sample at 17:27 GST. Here the sample pathologist's approval is given for you; on Run a sample you give it yourself.
Mariam's order is checked: from a licensed clinician, with consents on file. The cup is labelled and received.
Received 08:45 GST · the demonstration laboratory scientist
For
Mariam, 34
Ordered by
Dr Demonstration Clinician, checked against the Department of Health register
Consents
Collection and data sharing, on approved forms
Name in VERA
never stored: VERA knows Mariam only by a code
The order rules await the laboratory director's signature: on real data VERA refuses the order today because the order rules are not signed yet. Here a demonstration sign-off stands in, for this synthetic sample only.
At IRENA the order comes from the laboratory's own system for a real patient; here VERA makes a sample order for an invented person.
The Sysmex urine line measures the cup and sends 20 results to the laboratory system, as it does every day. VERA's code took 1 ms here.
Zone 2
At the analyser
The results become data, and VERA keeps a copy.
04
VERA™ takes a read-only copy
DoneVERA’s code: 101 ms
RenderVERA Edge enclosure with an NVIDIA DGX Spark, as designed
VERA copied the machine's results without touching the machine: it listens, and never sends anything back.
Copied
all 4,318 bytes; sent nothing back: 0 bytes to the analyser
Listen-only
the part that could send anything was removed before the first byte arrived
Kept in
a fresh database made for this run alone, closed when the run ends
On Prepaire's own computer VERA's read-only listener takes this copy from a mirror of the analyser's link, once it is switched on for that analyser; here the copy travels inside this one server.
VERA copied the machine's results without touching the machine: it listens, and never sends anything back. VERA's code took 101 ms here.
Zone 3
Sealed and kept at home
Encrypted before anything moves, and kept where it belongs.
05
Sealed and fingerprinted
Done
Before anything moves, VERA sealed the copy (1 message) under a key made for this run and fingerprinted it; its 2 entries are chained one to the next, with no break.
Sealed
1 message, encrypted (AES-256) under a key made for this run
Fingerprint
bbe96767cbf8… (of everything copied: change a single byte and the fingerprint changes)
Chain
2 entries, each linked to the one before: no break; re-read byte for byte
At IRENA the sealed copy then crosses the encrypted network by Nokia to the laboratory's own data centre; here everything stays on one server.
Before anything moves, VERA sealed the copy (1 message) under a key made for this run and fingerprinted it; its 2 entries are chained one to the next, with no break.
06
Where the data may go
Done
The rule asks what kind of data it is and where it would go, never whose it is: anyone's Sysmex urine line message gets the same answer.
The Sysmex urine line's own message, as VERA copied it4,318 bytes, sealed at station 05
On this siteAllowedTo the DGX Spark task service. The engine runs on this site, so the data stays here.
In a cloudRefusedTo the GPU pipeline server. An instrument's own signal never leaves the site. No pseudonymisation is recorded on this data, and VERA never assumes it. No legal approver has assessed sending this kind of data to this engine in a cloud.
Mariam's 20 results, as releasedthe results and the trail back to their evidence
On this siteAllowedTo the DGX Spark task service. The engine runs on this site, so the data stays here.
In a cloudRefusedTo the GPU pipeline server. Released results and the trails back to their evidence never leave the site. No pseudonymisation is recorded on this data, and VERA never assumes it. No legal approver has assessed sending this kind of data to this engine in a cloud.
The rule asks what kind of data it is and where it would go, never whose it is: anyone's Sysmex urine line message gets the same answer.
On Prepaire's own computer the same rule runs before every call to an analysis engine, and reads a legal approver's signed assessment where one is on record.
The rule asks what kind of data it is and where it would go, never whose it is: anyone's Sysmex urine line message gets the same answer.
Zone 4
Checked
Read, coded and checked, result by result.
07
Read and coded
DoneVERA’s code: 2 ms
20 results read from the sealed copy, each matched to the right cup and person.
Every result mapped to the national code list, in one standard unit.
Tube
IRN261129033, the cup on the specimen record
Result of the checks
ready for review (2 notes for the pathologist)
Identity
VERA never reads Mariam's name or ID number from the message: only Mariam's code and the tube
Checked
every part of the message and its check digits, the order of the records, the tube and the specimen type
Test menu
Prepaire's test menu, 129 tests
Coded
each result to its national code (LOINC), for example Urine colour → 5778-6
Released in parts
Sysmex UC-3500 (12 results) and Sysmex UF-5000 with UD-10 (8 results)
On real data today the gate quarantines this message: the Sysmex host-code table awaits the laboratory director's signature. The demonstration sign-off applies to this synthetic sample only.
20 results read from the sealed copy, each matched to the right cup and person. Every result mapped to the national code list, in one standard unit. VERA's code took 2 ms here.
08
Quality control and Mariam's own ranges
DoneVERA’s code: 5 ms
Every test is in control on Sysmex urine line: 20 results, controls checked by VERA itself.
Nothing dangerous, nothing unexpected. 7 results read against Mariam's own range: no real change.
Control rules
the standard Westgard rules: a small drift warns, a large one or a pattern stops the run
Controls
two levels every 8 h; the last run 16:54 GST, 30 min before the sample
Calibration
accepted 3 days ago, valid 30 days (the demonstration interval)
Records
captured by each analyser from a message VERA stored, within 10 minutes; none entered by hand
Graded controls
12 strip and flag results: negative and positive controls read their grades
Danger limits
5 rules: none reached
Change since last time
against the last result (40 days ago): no unexpected change
Own ranges
7 results with a personal range from 4 earlier tests
Identity
cup, vial, order and subject agree; specimen type matches every marker
On real data today QC is not evaluable: the QC rules and control targets await the laboratory director's signature. Demonstration targets and a synthetic control history stand in.
Every test is in control on Sysmex urine line: 20 results, controls checked by VERA itself. Nothing dangerous, nothing unexpected. 7 results read against Mariam's own range: no real change. VERA's code took 5 ms here.
Zone 5
Approved by people
Nothing leaves VERA until two people have signed.
09
The pathologist approves, a second person releases
DoneVERA’s code: 11 ms
The pathologist approved all 20 results, each bound to its exact value.
A second person released the results: 2 releases, every check on record.
Approved 17:27 GST · you, as the demonstration pathologist
Released 17:27 GST · you, as the second person
Approved by
You, as the demonstration pathologist
Approved at
17:27 GST
Approved
exactly as queued: each result bound to its value
Released by
You, as the second person, in the quality manager's role: on record, the releaser neither submitted nor reviewed the run
Release record
Sysmex UC-3500, sealed, fingerprint 60131130f083…
Release record
Sysmex UF-5000 with UD-10, sealed, fingerprint 949c7b657001…
On record
every check behind each result: quality control, holds, the review, the coding, the order and the tube's checks
A sample pathologist, in the sample lane only: on real data each pathologist signs in with their own account.
Release on a demonstration sign-off: the release record says so, and no real result can carry one.
The pathologist approved all 20 results, each bound to its exact value. A second person released the results: 2 releases, every check on record. VERA's code took 11 ms here.
10
Signed report, clinic and Malaffi
DoneVERA’s code: 11 ms
Lab report signed and checked against every item the regulator requires, ready for the clinic.
The results message for the clinic's system is built and checked: the same 20 results as the signed report, with Mariam's own ranges as the signed report prints them. It is not sent: a sample run never sends it, on the open copy or anywhere else.
The message for Malaffi, Abu Dhabi's health record exchange, is built and checked: 20 results, with Mariam's own ranges as the signed report prints them. A sample run never sends it.
Report
revision 1, 20 results
Report checked
all 18 items the regulator requires, in the PDF and in both electronic versions
Signed
with an advanced electronic signature, under a sample seal made for this run
References
7 read against Mariam's own range, 1 still learning, 12 graded in words; every measured result also carries the standard adult range, which L and H are read against
Authorised by
the laboratory director (sample), named on the signed Sample PDF
File
29,913 bytes, fingerprint 656b37a0b0f1…
Clinic message
the standard results message (HL7), 9,685 bytes, marked as a sample
Addressed to
Dr Demonstration Clinician, Sample Clinic (demonstration)
Clinic message checked
identical to the signed report, item by item
Own ranges in the clinic message
7 results with Mariam's own range in a note under the result, as the signed report prints it
Sending the clinic message
built and checked here; a real release's message goes to the hospital its order came from, once that hospital is listed and approved
Malaffi message checked
a national code on every result, and Mariam's Emirates ID where Malaffi expects it
Own ranges in the Malaffi message
7 results with Mariam's own range in a note under the result, as the signed report prints it
Sections
urine
Marked
as a training message, as Malaffi requires until it accepts a test message
Sending
built and checked here; the outbox sends a real release's message once, and a send needs the exchange's tables signed and its connection details set on the copy that sends
Every page is marked SAMPLE REPORT. The laboratory's own signing key and the laboratory director's signature stay for real reports.
Malaffi's code lists and message format await Malaffi onboarding and the laboratory director's signature; demonstration values stand in.
On Prepaire's own computer a signed report's message goes to the hospital its order came from, once that hospital's address is listed and the information security officer has approved it. The outbox sends a release's message to Malaffi once; a send needs the Malaffi tables signed and Malaffi's connection details set on the copy that sends.
Lab report signed and checked against every item the regulator requires, ready for the clinic. The results message for the clinic's system is built and checked: the same 20 results as the signed report, with Mariam's own ranges as the signed report prints them. It is not sent: a sample run never sends it, on the open copy or anywhere else. The message for Malaffi, Abu Dhabi's health record exchange, is built and checked: 20 results, with Mariam's own ranges as the signed report prints them. A sample run never sends it. VERA's code took 11 ms here.
Zone 6
Mariam's own record
The evidence comes back to the person it describes.
11
Mariam's knowledge graph and own ranges
DoneVERA’s code: 4 ms
20 new results added to Mariam's own encrypted knowledge graph, beside the 4 earlier tests.
Mariam's own ranges, read for 7 tests: no real change today.
Knowledge graph
100 results from 5 visits, 126 entries, 524 links
Encrypted
under Mariam's own key (AES-256): 225,225 bytes sealed, opened and checked
Reference graph
20 biomarkers linked to the reference knowledge graph
Method
Mariam's usual level and range for each test, from Mariam's own results
How much the person varies
the European database of how much each test varies within one person (EFLM), pending the laboratory director's sign-off
Tests with no published variation
7 tests: read against the spread of Mariam's own earlier results
Laboratory precision
sample figures, until the laboratory's own quality-control history is entered
Every result read against Mariam's own range is within it. This is not a diagnosis.
Written by VERA from these results, on this page.
Urine pH6.5Within Mariam's range · Own range 4.7–7.5, from 4 earlier results
Urine specific gravity1.015Within Mariam's range · Own range 1.005–1.028, from 4 earlier results
Urine urobilinogen0.2 mg/dLWithin Mariam's range · Own range 0.2–0.3 mg/dL, from 4 earlier results
Red cells in urine3 /µLWithin Mariam's range · Own range 2–10 /µL, from 4 earlier results
White cells in urine3 /µLWithin Mariam's range · Own range 1–9 /µL, from 4 earlier results
Urine epithelial cells2 /µLWithin Mariam's range · Own range 1–4 /µL, from 4 earlier results
On Prepaire's own computer the graph is kept, sealed under the person's own key, and grows with every visit; here it is built in this server's memory for this run, kept up to 30 minutes and never written to disk.
20 new results added to Mariam's own encrypted knowledge graph, beside the 4 earlier tests. Mariam's own ranges, read for 7 tests: no real change today. VERA's code took 4 ms here.
Sample data: the people, the staff and the orders on this page are invented, and every report is marked Sample. Where a rule table still waits for the laboratory director’s signature, a labelled demonstration sign-off stands in for these samples only; it can never apply to a real patient. A sample run sends nothing anywhere, and this copy remembers your last run for 30 minutes in this server’s memory only. Times are Gulf Standard Time (GST, UTC+4).