Seven launch lanes · every AXIOM domain maps onto this machinery
Modality lanes
Each lane is one kind of file from the lab: what the lab agrees to send, how VERA reads it, and what each result links to. The AXIOM SA 360 panel lists what feeds each lane.
Panel to machinery
AXIOM domain → ingestion lane
Every test on the panel has a lane. Every lane's results come out in the same shape and pass the same five checks.
- 4.1Blood intelligenceBlood chemistry
- 4.2Immune / SASPBlood chemistry
- 4.3Organ agesProteins
- 4.4EpigeneticsMethylation clocks
- 4.5Mito / fluxBlood chemistry
- 4.6MicrobiomeGut microbes
- 4.7EndocrineHormones
- 4.8One-carbonBlood chemistry
- 4.9Urine OAUrine metabolites
- 4.10ExposomeEnvironment
- 4.11WearablesWearables
- 4.12Derived indicesComputed from other results
- 4.13Genomics (optional)Whole genome
The seven launch lanes
What the lab sends, and how VERA™ reads it
- 1Lane 1In clinical reviewResults messages from the chemistry analysers
Blood chemistry
The clean-up of the old result messages and the translation of the laboratory's own codes to standard test codes are in clinical review.
Status: Adapter and gate live in this appRuns on the made-up results messages in the LIM Ingestor.
Status: Qualification requiredThe analysis it feeds: Roche cobas pure clinical chemistry and immunoassay
4.1 Blood intelligence4.2 Immune / SASP4.5 Mito / flux4.8 One-carbonWhat the lab sends
One results message per report, with each test's code, its value and unit, and the standard range.
How VERA™ reads it
VERA reads every value and converts it to one agreed unit per test, using only the laboratory's signed conversion table.
What it links to
Each test links to what it measures, its ranges and the conditions it can point to.
Run just now on its demo file: Chemistry results from the old Navify export, with its errors: quarantined. 12 rows read, 5 passed every check, 12 problems, 1 question.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: A test code without a signed translation stays held; VERA never guesses it.
- 2Lane 2In progressThe whole-genome file
Whole genome
A production genome file is being trialled. Separate calls for the hard-to-read medicine genes have been requested from the lab.
Status: Contract check live in this appChecks a genome file preview for its covered parts, quality scores and index.
Status: Qualification requiredThe analysis it feeds: Pharmacogenomics
4.13 Genomics (optional)What the lab sends
The genome file with the parts it covered marked, a quality score per call and an index; four hard-to-read genes called on their own, or a note that they were not.
How VERA™ reads it
VERA checks that the file is complete. Reading the genes that change how medicines work runs on the Spark.
What it links to
Gene results link to the published guidance on medicine response.
Run just now on its demo file: Genome file, a preview: held for a reviewer. 1 row read, 1 passed every check, 0 problems, 1 question.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: One medicine-processing gene, CYP2D6, is never released from a short-read genome alone.
- 3Lane 3Pending lab dataClock reports
Methylation clocks
Waiting for the laboratory's report format.
Status: Adapter live in this appReads the made-up clock report.
Status: Blocked: assay contract requiredThe analysis it feeds: Methylation assay router
4.4 EpigeneticsWhat the lab sends
A report with the clock's name and version, each organ's estimated age and the sample's quality figures.
How VERA™ reads it
VERA keeps one result per organ and records the clock version, because different versions cannot be compared.
What it links to
Organ ages link to a fixed list of organs; what they mean sits in the research evidence.
Run just now on its demo file: Methylation clock report: ready for review. 4 rows read, 4 passed every check, 0 problems, 0 questions.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: A methylation age from nanopore sequencing is not released until it is shown to agree with the array method.
- 4Lane 4In progressGut-microbe tables
Gut microbes
The metagenome delivery is under review. Whether the simple stool panel was run is being confirmed with the lab.
Status: Adapter live in this appReads the made-up gut-microbe table.
Status: Ready for the laboratory's validationThe analysis it feeds: Shotgun metagenomics
4.6 MicrobiomeWhat the lab sends
Each microbe's share of the sample with its taxonomy number and, where run, simple stool chemistry.
How VERA™ reads it
VERA reads each microbe's share; stool chemistry goes through the same checks as blood.
What it links to
Each microbe links to the taxonomy tree and to published links between microbes and conditions.
Run just now on its demo file: Gut-microbe table: ready for review. 6 rows read, 6 passed every check, 0 problems, 0 questions.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: Microbe results describe the sample; they are not findings until a reference from healthy people is in place.
- 5Lane 5PlannedMetabolite panels
Urine metabolites
Ready to wire: the same machinery as the blood lane.
Status: Planned
Status: Blocked: method contract requiredThe analysis it feeds: Organic-acid mass spectrometry
4.9 Urine OAWhat the lab sends
Each metabolite with its test code, unit and method, with the sample marked as urine.
How VERA™ reads it
Planned: read the same way as blood chemistry.
What it links to
Each test links to the metabolite it measures.
A file sent on this lane is refused at the gate: drop one to see.
Drop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded. - 6Lane 6Pending lab dataMessages from the Sysmex blood-count analyser
Blood count
KERNEL's Sysmex link is proven on its simulator. The code table awaits the laboratory director's signature.
Status: Adapter and gate live in this appRuns on messages from KERNEL's Sysmex simulator, and holds every one until the Sysmex code table is signed.
Status: Blocked: interface contract requiredThe analysis it feeds: Sysmex XR-1000 haematology
What the lab sends
One message per tube from the Sysmex XR-1000, captured byte for byte, with the tube's number and one line per count.
How VERA™ reads it
VERA reads each line, translates the analyser's codes through the signed Sysmex code table and runs the five checks. It never sends the analyser an order.
What it links to
Each count links to what it measures, its ranges and the conditions it can point to.
Run just now on its demo file: Blood count from the Sysmex XR-1000: quarantined. 20 rows read, 20 passed every check, 1 problem, 1 question.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: No result leaves the gate while the Sysmex code table is unsigned, and an unknown analyser code is never guessed.
- 7Lane 7Pending lab dataMessages from the Sysmex urine line
Urine test
KERNEL's urine-line link is proven on its simulator. The code table awaits the laboratory director's signature.
Status: Adapter and gate live in this appRuns on messages from KERNEL's Sysmex simulator, and holds every one until the Sysmex code table is signed.
Status: Blocked: interface contract requiredThe analysis it feeds: Sysmex urine line (U-WAM: UC-3500, UF-5000, UD-10)
What the lab sends
One message per tube from the Sysmex urine line (strip, particle counter and imaging), captured byte for byte.
How VERA™ reads it
VERA pairs each raw and final line, notes which module measured it and translates codes through the signed table. Crystals, mucus and yeast-like cells are reported as present or absent, never as counts.
What it links to
Each result links to what it measures, its ranges and the conditions it can point to.
Run just now on its demo file: Urine test from the Sysmex urine line: quarantined. 20 rows read, 20 passed every check, 1 problem, 2 questions.
Run this laneDrop your own file here or : a results message (HL7), an analyser file (ASTM), a table (CSV or TSV), a JSON file or a genome variant file (gVCF). It is read in this tab and never uploaded.Release rule: No urine result leaves the gate while the Sysmex code table is unsigned.
Expansion
+ AXIOM expansion lanes (same shape, same checks)
Proteomics organ ages (4.3) · saliva/hair endocrine (4.7) · exposome MS (4.10) · wearable streams (4.11) · derived indices (4.12). Each joins as an agreement with the lab, not as new machinery.