GenetiQ / VERA
Analysis and evidence
Check a laboratory package
Results travel from the instrument to a person's record in one package that says who and which sample, the instrument and its software, quality control and the laboratory's release checks. Load a package, change it, or drop your own. VERA's own validator answers, and the fingerprint of what you sent changes with every edit.
1Start from a package
2Change it and watch the answer
Load a sample package or drop your own: the switches appear for any package VERA can read.
The package itself, to read or edit
Compare a new engine with the current one
A new analysis engine replaces the current one only after both have read the same held-out participants, and the new one matches the truth in every group the policy names. The policy asks, in each group, for at least 100 participants, at least 95% right even at the low end of its range, and at most 5% disagreement with the current engine. Set up a comparison or paste your own: VERA's own evaluator decides.
1Set up the comparison
2The evidence collected so far
The comparison itself, to read or edit
Instrument analysis lanes
12 analytical selections in the reference register, for 10 AXIOM panel instruments in 8 families; 9 have an edge lane, and 9 of those are active in IRENA's register. Each software selection needs an approved build and validation for the installed assay.
Short-read germline whole-genome sequencing6 stages
Preserve the completed native run package and generated FASTQ, with sample sheet, read groups, base-conversion identity, checksums, and run metrics.
- Capture and source decoding
Seal native run evidence before a vendor-supported decoder produces open FASTQ.
- Read quality and identity controls
Measure read quality, library completeness, contamination, sample identity, and metadata consistency before calling.
- Alignment and small-variant calling
Produce coordinate-sorted alignment, callability evidence, and a normalised germline SNV/indel call set.
NVIDIA Parabricks deepvariant_germline · BWA-MEM2 · DeepVariant · GATK HaplotypeCaller
- CNV, structural, repeat, and mitochondrial calling
Recover clinically relevant variant classes not represented reliably by a small-variant VCF.
- Annotation and governed classification
Add versioned consequence, allele-frequency, phenotype, guideline, and literature evidence without treating annotation as final clinical classification.
- Evidence packaging and independent release
Package complete call-set pointers and only reviewed reportable findings for controlled KG projection.
VERA genomic evidence packager
Output: Pointers to immutable call sets plus independently released findings, evidence sources, intended use, uncertainty, consent, review, and revocation state.
PacBio HiFi germline whole-genome sequencing4 stages
Preserve native run metadata, HiFi BAM, kinetics where produced, sample sheet, software versions, and checksums.
- Native Revio capture
Seal the completed Revio run package and HiFi read evidence.
- HiFi human WGS workflow
Run the tested PacBio WDL for alignment, small variants, structural variants, repeats, phasing, and QC.
PacBio HiFi-human-WGS-WDL · NVIDIA Parabricks pacbio_germline
- Native CpG evidence
Produce base-resolution methylation calls for downstream assay-specific models.
- Annotation, packaging, and release
Apply the same governed classification boundary as short-read WGS while preserving long-read-specific evidence.
Ensembl VEP · VERA genomic evidence packager
Output: Released long-read genomic findings and methylation features with immutable call-set pointers and full method provenance.
Oxford Nanopore germline whole-genome sequencing4 stages
Preserve POD5, MinKNOW metadata, sequencing summary, exact Dorado basecalling and modified-base model identities, read groups, and checksums.
- POD5 and MinKNOW capture
Seal raw signal and run metadata before basecalling.
- Basecalling and modified bases
Generate aligned-ready reads with exact model provenance.
- Human variation workflow
Call small variants, SV, CNV, STR, phasing, and modified-base summaries.
EPI2ME wf-human-variation · NVIDIA Parabricks ont_germline · Clair3 and Sniffles2
- Annotation, packaging, and release
Project only governed findings while retaining complete nanopore evidence in DRS.
Ensembl VEP · VERA genomic evidence packager
Output: Released nanopore findings, exact basecaller/model provenance, and immutable pointers to raw signal and call sets.
Shotgun metagenomics6 stages
Preserve reads or raw signal, extraction and library batch, specimen handling, wet controls, spike-in identity when used, host-depletion reference, database snapshots, and every parameter.
- Read capture and control reconciliation
Seal the sample reads and bind extraction blanks, no-template controls, positive mock community, and spike-in to the same batch.
VERA metagenomics intake adapter
- Read QC and host depletion
Trim and filter low-quality sequence, quantify host fraction, and create a non-human analytical derivative while preserving source custody.
- Taxonomic profiling
Produce one canonical marker-based profile and one independent k-mer comparator.
- Functional pathway profiling
Estimate gene-family and pathway abundance from host-depleted reads using frozen biological databases.
- AMR evidence and optional assembly
Generate separately labelled antimicrobial-resistance evidence and a research-only MAG branch where protocol and depth support it.
- Semantic normalisation and release
Preserve compositional meaning, control state, uncertainty, and method identity before KG projection.
VERA metagenomics evidence packager
Output: Released taxon, pathway, and AMR features with measurement basis, controls, database snapshots, uncertainty, longitudinal comparability, and DRS pointers.
Pharmacogenomics3 stages
Retain aligned reads, small and structural calls, phasing, assay coverage, reference assembly, caller models, and outside-call provenance.
- Gene-aware allele calling
Resolve small variants, CNV, SV, hybrids, phasing, HLA, and mitochondrial evidence using the method qualified for each gene.
Aldy 4 · StellarPGx · PyPGx
- Guideline interpretation
Translate validated gene calls into versioned CPIC, DPWG, and label evidence.
- Pharmacist review and release
Release a medication-specific action only under consent, current medication context, and professional governance.
VERA PGx evidence packager
Output: Released PGx genotype, phenotype, guideline, medication-context, and pharmacist-review evidence.
Methylation assay router3 stages
The assay chemistry, tissue, source artefact, normalisation method, probe or CpG set, model weights, training cohort, and batch controls are mandatory.
- Assay and source classification
Identify the chemistry and required analytical branch without guessing from the report label.
VERA assay contract validator
- Platform-specific methylation measurement
Generate normalised CpG or probe measurements using the branch appropriate to the source assay.
SeSAMe or minfi · nf-core/methylseq · Jasmine and MethBat · Dorado and modkit
- Validated age model and release
Apply only a licensed, tissue-appropriate, independently validated clock with uncertainty and repeatability evidence.
Output: CpG or probe measurements and any separately validated age estimate with model, tissue, batch, uncertainty, and source provenance.
Illumina iScan genotyping and methylation arrays3 stages
Preserve the red and green IDAT pair, scan metrics, Effective.cfg, available TIFF or JPEG images, sample map, BeadChip barcode, exact manifest and cluster-file identities, iScan Control Software version and checksums.
- IDAT and scan evidence capture
Seal source intensity, scan configuration, images and metrics before normalisation or genotype calling.
- Assay-specific normalisation
Resolve the exact BeadChip contract, then normalise within the correct genotyping or methylation branch.
- Array evidence packaging and release
Package probe-level provenance, QC and only independently reviewed findings for graph projection.
VERA array evidence packager
Output: Released array genotypes or methylation features with probe, manifest, cluster, normalisation, batch, uncertainty and immutable IDAT provenance.
Roche cobas pure clinical chemistry and immunoassay3 stages
Preserve original messages and acknowledgements, message-control IDs, assay and module identity, method, reagent and calibrator lots, QC state, units, source standard ranges, flags, precision, timestamps and amendments.
- Host result, QC and calibration capture
Seal the complete Roche evidence envelope before terminology or unit normalisation.
- Code, unit and reference normalisation
Map source observations to governed LOINC, UCUM and FHIR semantics while preserving every original field.
VERA clinical observation normaliser
- Clinical evidence packaging and release
Release only assay-scoped observations whose identity, QC, calibration, units and reference provenance pass.
VERA clinical lab evidence packager
Output: Released quantitative or qualitative observations with source and normalised values, method, matrix, units, flags, reference provenance, QC and immutable message pointers.
Roche cobas i 601 clinical mass spectrometry3 stages
Preserve the original result and audit envelope, method and Ionify assay identity, calibration curve, internal standards, reagent lots, QC, flags, measuring range, timestamps and any documented native-data export.
- Result, calibration and QC capture
Seal the complete supported Roche evidence envelope before normalisation.
- Clinical normalisation and optional research comparison
Normalise released assay results and, only when source data permits, run a separately labelled research comparison.
VERA clinical mass-spec normaliser · Skyline
- Mass-spec evidence packaging and release
Release only results within the qualified Ionify assay menu and analytical scope.
VERA clinical lab evidence packager
Output: Released targeted analyte results with method, calibration, internal-standard, QC, source and normalised values, reference provenance and immutable evidence pointers.
Sysmex XR-1000 haematology3 stages
Preserve original host messages, extended data when licensed, analyser and sampler identities, software versions, reagent and QC lots, flags, rerun or reflex state, precision, units, timestamps and amendments.
- CBC, flag, QC and extended-data capture
Seal original Sysmex evidence before code and unit normalisation.
- Haematology normalisation
Map the validated parameter menu to governed LOINC and UCUM identities while retaining source values and flags.
VERA haematology normaliser
- Haematology evidence packaging and release
Release only observations with valid identity, QC, calibration, reference provenance and analyser state.
VERA clinical lab evidence packager
Output: Released haematology observations with source and normalised values, analyser flags, specimen, method, units, QC, reference provenance and immutable evidence pointers.
Sysmex urine line (U-WAM: UC-3500, UF-5000, UD-10)3 stages
Preserve exact UF, UC, UD or related module identities, original host messages, supported images or scattergrams, software and middleware, methods, reagent and QC lots, flags, precision, units, timestamps and amendments.
- Module-aware urine evidence capture
Seal the complete supported result, image, flag and QC envelope from the identified module set.
- Urinalysis normalisation
Map chemistry and particle observations to governed code and unit identities while preserving module and source semantics.
VERA urinalysis normaliser
- Urinalysis evidence packaging and release
Release only module-scoped observations whose identity, QC, flags and method provenance pass.
VERA clinical lab evidence packager
Output: Released urine chemistry and particle observations with source and normalised values, module, method, flags, units, QC, reference provenance and immutable evidence pointers.
Organic-acid mass spectrometry3 stages
Retain native acquisition files, method, calibrators, internal standards, blanks, pooled QC, integration parameters, library identity, and open mzML.
- Native capture and mzML conversion
Seal the native acquisition package and produce an open derivative without deleting source evidence.
- Peak processing and targeted quantitation
Perform transparent chromatographic processing while preserving the validated targeted assay's calibrator and internal-standard semantics.
- Semantic normalisation and release
Release identified and quantified analytes only within the validated method scope.
VERA metabolomics evidence packager
Output: Validated analyte concentrations, units, identity confidence, QC, method, standard ranges, and immutable raw-data pointers.
Which engine runs each genomic stage, what its approval still needs and where the data may go: Genomic pipeline selection. Every call VERA makes to an analysis engine is one row of the API call log.