GenetiQ / VERA

Analysis and evidence

Trace every analytical result from its instrument and software to the personalised twin.
Your packageTo check
Load, change or drop a package below
Results in it–
Counted when it is checked
Your engine comparisonTo evaluate
Set it up under Compare a new engine
Participants compared–
Counted when it is evaluated

Check a laboratory package

Results travel from the instrument to a person's record in one package that says who and which sample, the instrument and its software, quality control and the laboratory's release checks. Load a package, change it, or drop your own. VERA's own validator answers, and the fingerprint of what you sent changes with every edit.

1Start from a package

2Change it and watch the answer

Load a sample package or drop your own: the switches appear for any package VERA can read.

The package itself, to read or edit

Instrument analysis lanes

12 analytical selections in the reference register, for 10 AXIOM panel instruments in 8 families; 9 have an edge lane, and 9 of those are active in IRENA's register. Each software selection needs an approved build and validation for the installed assay.

Register a pipeline
Short-read germline whole-genome sequencing6 stages

Preserve the completed native run package and generated FASTQ, with sample sheet, read groups, base-conversion identity, checksums, and run metrics.

  1. Capture and source decoding

    Seal native run evidence before a vendor-supported decoder produces open FASTQ.

    Element Bases2Fastq · MGI CAL-to-FASTQ converter

  2. Read quality and identity controls

    Measure read quality, library completeness, contamination, sample identity, and metadata consistency before calling.

    FastQC and MultiQC · VerifyBamID2

  3. Alignment and small-variant calling

    Produce coordinate-sorted alignment, callability evidence, and a normalised germline SNV/indel call set.

    NVIDIA Parabricks deepvariant_germline · BWA-MEM2 · DeepVariant · GATK HaplotypeCaller

  4. CNV, structural, repeat, and mitochondrial calling

    Recover clinically relevant variant classes not represented reliably by a small-variant VCF.

    Manta · GATK germline CNV workflow · ExpansionHunter

  5. Annotation and governed classification

    Add versioned consequence, allele-frequency, phenotype, guideline, and literature evidence without treating annotation as final clinical classification.

    Ensembl Variant Effect Predictor

  6. Evidence packaging and independent release

    Package complete call-set pointers and only reviewed reportable findings for controlled KG projection.

    VERA genomic evidence packager

Output: Pointers to immutable call sets plus independently released findings, evidence sources, intended use, uncertainty, consent, review, and revocation state.

PacBio HiFi germline whole-genome sequencing4 stages

Preserve native run metadata, HiFi BAM, kinetics where produced, sample sheet, software versions, and checksums.

  1. Native Revio capture

    Seal the completed Revio run package and HiFi read evidence.

    SMRT Link export adapter

  2. HiFi human WGS workflow

    Run the tested PacBio WDL for alignment, small variants, structural variants, repeats, phasing, and QC.

    PacBio HiFi-human-WGS-WDL · NVIDIA Parabricks pacbio_germline

  3. Native CpG evidence

    Produce base-resolution methylation calls for downstream assay-specific models.

    PacBio Jasmine and MethBat

  4. Annotation, packaging, and release

    Apply the same governed classification boundary as short-read WGS while preserving long-read-specific evidence.

    Ensembl VEP · VERA genomic evidence packager

Output: Released long-read genomic findings and methylation features with immutable call-set pointers and full method provenance.

Oxford Nanopore germline whole-genome sequencing4 stages

Preserve POD5, MinKNOW metadata, sequencing summary, exact Dorado basecalling and modified-base model identities, read groups, and checksums.

  1. POD5 and MinKNOW capture

    Seal raw signal and run metadata before basecalling.

    MinKNOW read-only export adapter

  2. Basecalling and modified bases

    Generate aligned-ready reads with exact model provenance.

    Dorado

  3. Human variation workflow

    Call small variants, SV, CNV, STR, phasing, and modified-base summaries.

    EPI2ME wf-human-variation · NVIDIA Parabricks ont_germline · Clair3 and Sniffles2

  4. Annotation, packaging, and release

    Project only governed findings while retaining complete nanopore evidence in DRS.

    Ensembl VEP · VERA genomic evidence packager

Output: Released nanopore findings, exact basecaller/model provenance, and immutable pointers to raw signal and call sets.

Shotgun metagenomics6 stages

Preserve reads or raw signal, extraction and library batch, specimen handling, wet controls, spike-in identity when used, host-depletion reference, database snapshots, and every parameter.

  1. Read capture and control reconciliation

    Seal the sample reads and bind extraction blanks, no-template controls, positive mock community, and spike-in to the same batch.

    VERA metagenomics intake adapter

  2. Read QC and host depletion

    Trim and filter low-quality sequence, quantify host fraction, and create a non-human analytical derivative while preserving source custody.

    KneadData · FastQC and MultiQC

  3. Taxonomic profiling

    Produce one canonical marker-based profile and one independent k-mer comparator.

    MetaPhlAn · Kraken2 and Bracken

  4. Functional pathway profiling

    Estimate gene-family and pathway abundance from host-depleted reads using frozen biological databases.

    HUMAnN

  5. AMR evidence and optional assembly

    Generate separately labelled antimicrobial-resistance evidence and a research-only MAG branch where protocol and depth support it.

    AMRFinderPlus · RGI and CARD · nf-core/mag

  6. Semantic normalisation and release

    Preserve compositional meaning, control state, uncertainty, and method identity before KG projection.

    VERA metagenomics evidence packager

Output: Released taxon, pathway, and AMR features with measurement basis, controls, database snapshots, uncertainty, longitudinal comparability, and DRS pointers.

Pharmacogenomics3 stages

Retain aligned reads, small and structural calls, phasing, assay coverage, reference assembly, caller models, and outside-call provenance.

  1. Gene-aware allele calling

    Resolve small variants, CNV, SV, hybrids, phasing, HLA, and mitochondrial evidence using the method qualified for each gene.

    Aldy 4 · StellarPGx · PyPGx

  2. Guideline interpretation

    Translate validated gene calls into versioned CPIC, DPWG, and label evidence.

    PharmCAT

  3. Pharmacist review and release

    Release a medication-specific action only under consent, current medication context, and professional governance.

    VERA PGx evidence packager

Output: Released PGx genotype, phenotype, guideline, medication-context, and pharmacist-review evidence.

Methylation assay router3 stages

The assay chemistry, tissue, source artefact, normalisation method, probe or CpG set, model weights, training cohort, and batch controls are mandatory.

  1. Assay and source classification

    Identify the chemistry and required analytical branch without guessing from the report label.

    VERA assay contract validator

  2. Platform-specific methylation measurement

    Generate normalised CpG or probe measurements using the branch appropriate to the source assay.

    SeSAMe or minfi · nf-core/methylseq · Jasmine and MethBat · Dorado and modkit

  3. Validated age model and release

    Apply only a licensed, tissue-appropriate, independently validated clock with uncertainty and repeatability evidence.

    Assay-specific biological-age model

Output: CpG or probe measurements and any separately validated age estimate with model, tissue, batch, uncertainty, and source provenance.

Illumina iScan genotyping and methylation arrays3 stages

Preserve the red and green IDAT pair, scan metrics, Effective.cfg, available TIFF or JPEG images, sample map, BeadChip barcode, exact manifest and cluster-file identities, iScan Control Software version and checksums.

  1. IDAT and scan evidence capture

    Seal source intensity, scan configuration, images and metrics before normalisation or genotype calling.

    iScan Control Software read-only output adapter

  2. Assay-specific normalisation

    Resolve the exact BeadChip contract, then normalise within the correct genotyping or methylation branch.

    GenomeStudio or AutoConvert · SeSAMe · minfi

  3. Array evidence packaging and release

    Package probe-level provenance, QC and only independently reviewed findings for graph projection.

    VERA array evidence packager

Output: Released array genotypes or methylation features with probe, manifest, cluster, normalisation, batch, uncertainty and immutable IDAT provenance.

Roche cobas pure clinical chemistry and immunoassay3 stages

Preserve original messages and acknowledgements, message-control IDs, assay and module identity, method, reagent and calibrator lots, QC state, units, source standard ranges, flags, precision, timestamps and amendments.

  1. Host result, QC and calibration capture

    Seal the complete Roche evidence envelope before terminology or unit normalisation.

    Roche cobas pure host-interface adapter

  2. Code, unit and reference normalisation

    Map source observations to governed LOINC, UCUM and FHIR semantics while preserving every original field.

    VERA clinical observation normaliser

  3. Clinical evidence packaging and release

    Release only assay-scoped observations whose identity, QC, calibration, units and reference provenance pass.

    VERA clinical lab evidence packager

Output: Released quantitative or qualitative observations with source and normalised values, method, matrix, units, flags, reference provenance, QC and immutable message pointers.

Roche cobas i 601 clinical mass spectrometry3 stages

Preserve the original result and audit envelope, method and Ionify assay identity, calibration curve, internal standards, reagent lots, QC, flags, measuring range, timestamps and any documented native-data export.

  1. Result, calibration and QC capture

    Seal the complete supported Roche evidence envelope before normalisation.

    Roche cobas i 601 host-interface adapter

  2. Clinical normalisation and optional research comparison

    Normalise released assay results and, only when source data permits, run a separately labelled research comparison.

    VERA clinical mass-spec normaliser · Skyline

  3. Mass-spec evidence packaging and release

    Release only results within the qualified Ionify assay menu and analytical scope.

    VERA clinical lab evidence packager

Output: Released targeted analyte results with method, calibration, internal-standard, QC, source and normalised values, reference provenance and immutable evidence pointers.

Sysmex XR-1000 haematology3 stages

Preserve original host messages, extended data when licensed, analyser and sampler identities, software versions, reagent and QC lots, flags, rerun or reflex state, precision, units, timestamps and amendments.

  1. CBC, flag, QC and extended-data capture

    Seal original Sysmex evidence before code and unit normalisation.

    Sysmex XR-Series host-interface adapter

  2. Haematology normalisation

    Map the validated parameter menu to governed LOINC and UCUM identities while retaining source values and flags.

    VERA haematology normaliser

  3. Haematology evidence packaging and release

    Release only observations with valid identity, QC, calibration, reference provenance and analyser state.

    VERA clinical lab evidence packager

Output: Released haematology observations with source and normalised values, analyser flags, specimen, method, units, QC, reference provenance and immutable evidence pointers.

Sysmex urine line (U-WAM: UC-3500, UF-5000, UD-10)3 stages

Preserve exact UF, UC, UD or related module identities, original host messages, supported images or scattergrams, software and middleware, methods, reagent and QC lots, flags, precision, units, timestamps and amendments.

  1. Module-aware urine evidence capture

    Seal the complete supported result, image, flag and QC envelope from the identified module set.

    Sysmex UN-Series host-interface adapter

  2. Urinalysis normalisation

    Map chemistry and particle observations to governed code and unit identities while preserving module and source semantics.

    VERA urinalysis normaliser

  3. Urinalysis evidence packaging and release

    Release only module-scoped observations whose identity, QC, flags and method provenance pass.

    VERA clinical lab evidence packager

Output: Released urine chemistry and particle observations with source and normalised values, module, method, flags, units, QC, reference provenance and immutable evidence pointers.

Organic-acid mass spectrometry3 stages

Retain native acquisition files, method, calibrators, internal standards, blanks, pooled QC, integration parameters, library identity, and open mzML.

  1. Native capture and mzML conversion

    Seal the native acquisition package and produce an open derivative without deleting source evidence.

    SCIEX MS Data Converter · ProteoWizard msconvert

  2. Peak processing and targeted quantitation

    Perform transparent chromatographic processing while preserving the validated targeted assay's calibrator and internal-standard semantics.

    MZmine 4 · OpenMS

  3. Semantic normalisation and release

    Release identified and quantified analytes only within the validated method scope.

    VERA metabolomics evidence packager

Output: Validated analyte concentrations, units, identity confidence, QC, method, standard ranges, and immutable raw-data pointers.

Which engine runs each genomic stage, what its approval still needs and where the data may go: Genomic pipeline selection. Every call VERA makes to an analysis engine is one row of the API call log.

Demonstration copy