VERA validation campaigns

Before VERA may release a clinical result from an analyser, the laboratory tests that VERA reads that analyser correctly, and the laboratory director approves what was tested. Each test is a campaign.
Laboratory room lined with enclosed instruments

DemonstrationSample campaigns: invented records and invented staff. Open one to try each step; nothing is recorded. About the samples

Campaigns

3 campaigns

Open a campaign to see what was tested, the evidence, and the step that comes next.

CampaignOpenedEvidenceEvidence decisionWhere it stands, and what comes next
Sample campaign
23 Nov 20268 records
7 passed, 1 failed
No decision yetOpen: evidence being gathered
Next step: the evidence decision. VERA scores the records when the quality manager or laboratory director asks, signed in.
Sample campaign
16 Nov 202642 records
42 passed, 0 failed
Sufficient for monitored useWaiting for the laboratory director
Next step: the approval of the scope. The laboratory director takes this step, signed in, and nobody else can.
Sample campaign
9 Nov 202642 records
42 passed, 0 failed
Sufficient for monitored useApproved, not in force on this copy
This copy is outside the scope.
The scope is approved. No step is waiting. The laboratory director can withdraw the approval at any time, signed in.

This copy of VERA

Demonstration

On a laboratory's own VERA the scope check holds every clinical result back until an approved scope covers what the copy runs.

Release
Release vera-2026.11.29-4 (build bf941dc)
Platform
sha256:201f7b5c491c…
Clinical tables
20 tables, each named by a digest, a fingerprint of its content

Of the 21 tables every clinical release checks, 20 are the clinical tables a validation scope names by digest and 1 is the table of validated VERA releases; the laboratory director signs each, and 5 of the 20 also need the quality manager.

About the sample campaigns

Demonstration

This copy of VERA is an open demonstration. The campaigns on this page are samples: invented records and three invented members of staff, read, scored and compared by the code a laboratory's own VERA runs. The analysers, the clinical tables and their digests are this copy's own.

Two steps need signed-in people: the evidence decision (the quality manager or the laboratory director) and the approval of the scope (the laboratory director).

On this copy each step of a campaign can be tried as one of the invented members of staff. The answer comes from the same checks and the same scoring as on a laboratory's own VERA. What is tried is held in the page, sent with each step, and gone on leaving it.

On a laboratory's own VERA the approval is also checked against the signed staff register.

Who takes each step, and why nobody else may

  • Recording the evidence

    A quality manager, laboratory scientist or laboratory director, each signed in.

    Each record is one test file run by one operator on one reagent lot at one site. The same record entered twice is refused, and it is scored once.

  • The evidence decision

    The quality manager or laboratory director, signed in.

    Nobody types the decision in: VERA scores the records under the evidence policy and records the score with its reason. Any other sign-in is refused, and so is a request with no sign-in.

  • Approving the scope

    The laboratory director only, signed in and listed in the signed staff register, with a licence number, as valid on the day.

    The quality manager cannot approve: the decision is a score, and the approval is the laboratory director's own act. A laboratory director who recorded evidence of the campaign cannot approve it either: a person does not approve tests they performed.

  • Withdrawing an approval

    The laboratory director, signed in.

    A withdrawal names the approval it ends, with a reason. Both stay on record; nothing is changed or deleted.

What ends an approved scope

  • A changed clinical table

    The scope names every clinical table by the digest of its content, so a copy on which one value of one table has changed is outside the scope until a campaign for the new content is approved.

  • A new build

    The scope names one numbered release and the two parts of the software built from it (the platform, and the worker that runs the pipelines), so a copy that runs any other release or any other build of a part is outside the scope until a campaign for that build is approved.

  • A withdrawal

    The laboratory director may withdraw the approval at any time, and it ends at once, also for a release already being prepared.

  • A later rejection

    When a later campaign of the same scope ends with the decision that the evidence is not sufficient, the earlier approval ends with it.

Demonstration copy