Validation

VERA validation campaign

One campaign in four steps, from what was tested to the laboratory director's approval. The step that comes next is first on the page.

All validation campaigns

DemonstrationA sample campaign: invented records and invented staff. Every step can be tried on this page, and nothing is recorded. About the samples

Roche cobas pure (c 303 and e 402): Clinical chemistry, version 1

Waiting for the laboratory director

VERA's evidence decision closed the campaign. The scope releases nothing until the laboratory director approves it. Opened 16 Nov 2026, closed 20 Nov 2026.

Next step: the approval of the scope

Demonstration

The laboratory director takes this step, and nobody else can.

You approve the latest evidence decision for exactly the scope this campaign recorded. VERA checks the staff register before it records the approval.

The button opens once both entries are filled in.

On a laboratory's own VERA the approval also needs the signed staff register to list the laboratory director, with a licence number, as valid on the day.

A demonstration: the step is checked and answered by the rules of a laboratory's own VERA, on the sample's invented records. Nothing is recorded, and what you try is gone when you leave this page.

  1. Step 1Done
    What was tested

    The campaign names one analyser, one assay protocol, one release of VERA with its two parts of software, one pipeline and every clinical table.

    Recorded when the campaign is opened, by the quality manager, laboratory director or platform administrator.

  2. Step 2Done
    The evidence

    42 records: 42 passed, 0 failed.

    Recorded by a quality manager, laboratory scientist or laboratory director.

  3. Step 3Done
    The evidence decision

    Sufficient for monitored use, recorded on 20 Nov 2026.

    Scored by VERA when the quality manager or laboratory director asks.

  4. Step 4Next
    The approval

    Waiting for the laboratory director.

    Given by the laboratory director, and by nobody else.

Step 1 What was tested

This copy is outside it

Who: Recorded when the campaign is opened, by the quality manager, laboratory director or platform administrator.

The scope is exactly what was tested: one analyser, one assay protocol, one release of VERA and every clinical table it reads. Each item is named by a digest, a fingerprint of its content: change one value and the digest changes. An approval covers a copy of VERA only while every item is the same.

Analyser
Roche cobas pure (c 303 and e 402)Entry CP-CP-000001 of the asset register
Assay protocol
Clinical chemistry, version 1
Release of VERA
vera-2026.11.29-4 (build bf941dc)This copy runs the same.
Clinical tables
20 tablesEvery table on this copy has the content the scope names.
All 20 tables of the scope, each with its digest
TableWhat it decidesDigest of its contentAgainst this copy
Analyser flags and interference limits
The releasable analyser flags and index limits631357e70edf…Same as this copy
Biological variation
The biological variation behind personal ranges794171435ee3…Same as this copy
Calculated indices
The calculated indicescd8fed5cec3b…Same as this copy
Coded references
The coded references on the report2feb8209f959…Same as this copy
Critical values
The critical limitsfafc8b999ba1…Same as this copy
Critical-result escalation
The critical-call clock and escalation chain1fbdc424c734…Same as this copy
Delta checks
The delta checks4fb6a0dc7dc7…Same as this copy
Genotype starting ranges
The genotype-specific starting ranges of personal rangesaed748ac6fe5…Same as this copy
KERNEL's code crosswalk
KERNEL's local codes to LOINCd2ab641633be…Same as this copy
Laboratory details on the report
The laboratory facts the report printsf2d8b5852f9e…Same as this copy
Limits of the intake checks
The parameters of the ingestion gate's five checksc489448479fc…Same as this copy
Malaffi message profile
The Malaffi message profilee68294f3b449…Same as this copy
Malaffi section map
The Malaffi section of each marker904ea78c91ec…Same as this copy
Order rules
The order rules and pre-analytical limits6fc79d6c9275…Same as this copy
QC rules and control targets
The QC rules, targets and calibration intervals1b81ca0d91fb…Same as this copy
Staff register
Who may authorise a report231e232e6166…Same as this copy
Standard ranges
The standard ranges by sex and agefef8bcb6c604…Same as this copy
Sysmex host codes
The Sysmex host codesfa77610b6bd5…Same as this copy
Test catalogue and code map
The catalogue: each marker's code, unit, specimen and tube (the code map and unit table)1a35793f1f79…Same as this copy
Unit conversions
The unit conversions8edb4694b586…Same as this copy
The software of the scope, each part with its digest
Platform
sha256:201f7b5c491c…This copy runs the same.
Worker, which runs the pipelines
sha256:34287f72d5f8…Compared once this copy is told this part's digest, when it is installed for a laboratory.
Pipeline
ad2eea98f53b…
Software that was tested
Sample result packager, version sample
List of test files
d24abd40238b…

Step 2 The evidence

42 records: 42 passed, 0 failed

Who: Recorded by a quality manager, laboratory scientist or laboratory director.

Each record is one test file with a known expected result, run by one operator on one reagent lot at one site. It passes when the output agrees with the expected result. A record weighs more the further it is from a single run: another operator, another lot, another site, an outside sample.

Kind of evidenceWeight of one recordRecordsPassed
One run
11010
Another operator
1.2588
Another reagent lot
1.588
Another site
288
External proficiency sample
388
Every record, with its result (42)
Test fileResultKindOperator, lot, siteDigest of the outputRecorded
SAMPLE-FILE-001
PassedOne runsample-operator-1, sample-lot-A, sample-site-128be557e6334…16 Nov 2026, 09:47 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-002
PassedOne runsample-operator-1, sample-lot-A, sample-site-16057caaa154d…16 Nov 2026, 10:34 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-003
PassedOne runsample-operator-1, sample-lot-A, sample-site-19d929d04efb1…16 Nov 2026, 11:21 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-004
PassedOne runsample-operator-1, sample-lot-A, sample-site-192a7c5a9e3d1…16 Nov 2026, 12:08 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-005
PassedOne runsample-operator-1, sample-lot-A, sample-site-1745efd073099…16 Nov 2026, 12:55 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-006
PassedOne runsample-operator-1, sample-lot-A, sample-site-15f2e40cd1146…16 Nov 2026, 13:42 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-007
PassedOne runsample-operator-1, sample-lot-A, sample-site-107b1165afbc0…16 Nov 2026, 14:29 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-008
PassedOne runsample-operator-1, sample-lot-A, sample-site-12849e20b1b65…16 Nov 2026, 15:16 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-009
PassedOne runsample-operator-1, sample-lot-A, sample-site-18dad7e1217b0…16 Nov 2026, 16:03 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-010
PassedOne runsample-operator-1, sample-lot-A, sample-site-1709bd297f572…16 Nov 2026, 16:50 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-011
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-12ee316ab9cba…16 Nov 2026, 17:37 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-012
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-152da6bfdf61d…16 Nov 2026, 18:24 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-013
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-1b103fbc55bdc…16 Nov 2026, 19:11 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-014
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-1cb381f7245bf…16 Nov 2026, 19:58 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-015
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-1302e78bf3046…16 Nov 2026, 20:45 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-016
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-1b6a881c3eb85…16 Nov 2026, 21:32 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-017
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-10235a9a4ff10…16 Nov 2026, 22:19 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-018
PassedAnother operatorsample-operator-2, sample-lot-A, sample-site-1eb1c6e9d4178…16 Nov 2026, 23:06 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-019
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-1745dc0d1e339…16 Nov 2026, 23:53 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-020
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-1f4555221ccb9…17 Nov 2026, 00:40 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-021
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-149672196b6eb…17 Nov 2026, 01:27 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-022
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-1f3449f0e5009…17 Nov 2026, 02:14 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-023
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-1ee8cb75308bb…17 Nov 2026, 03:01 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-024
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-1a126fd26d6ee…17 Nov 2026, 03:48 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-025
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-16b4be42d158d…17 Nov 2026, 04:35 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-026
PassedAnother reagent lotsample-operator-1, sample-lot-B, sample-site-13ffcd28550d8…17 Nov 2026, 05:22 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-027
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-2490df0b20259…17 Nov 2026, 06:09 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-028
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-2966d695a3333…17 Nov 2026, 06:56 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-029
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-2e555b0d929dd…17 Nov 2026, 07:43 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-030
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-284985c308c7f…17 Nov 2026, 08:30 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-031
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-2d09687714a50…17 Nov 2026, 09:17 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-032
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-24bc6283aab72…17 Nov 2026, 10:04 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-033
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-26fe60f78743f…17 Nov 2026, 10:51 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-034
PassedAnother sitesample-operator-1, sample-lot-A, sample-site-2b44a91348ac1…17 Nov 2026, 11:38 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-035
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-schemeffe601009e53…17 Nov 2026, 12:25 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-036
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme1d863d2e6168…17 Nov 2026, 13:12 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-037
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme2fe85cef3669…17 Nov 2026, 13:59 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-038
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme10949bd1315b…17 Nov 2026, 14:46 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-039
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-schemea26406dc7dec…17 Nov 2026, 15:33 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-040
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme975a624a996c…17 Nov 2026, 16:20 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-041
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme27bc45c22685…17 Nov 2026, 17:07 GST
Sign-in Sample laboratory scientist
SAMPLE-FILE-042
PassedExternal proficiency samplesample-operator-1, sample-lot-A, sample-scheme34fd6f77231a…17 Nov 2026, 17:54 GST
Sign-in Sample laboratory scientist

Step 3 The evidence decision

Sufficient for monitored use

Who: Scored by VERA when the quality manager or laboratory director asks.

Nobody types this decision in. VERA scores the records under the laboratory's evidence policy and records the score with its reason. A decision that the evidence is sufficient, or that it is not, closes the campaign.

Every mandatory check passed, and VERA's output agreed with the expected results often enough for the policy's limit for restricted, monitored use. Counted by the policy's weights, the records add up to 72. From them VERA works out how often its output agrees with the expected result: in at least 95.0% of runs. The figure is set low on purpose: the chance that the true share is lower is 2.5%. The policy asks for at least 95.0% for restricted, monitored use. For use without that restriction it asks for at least 99.0%, from records that add up to 30 or more.

Recorded 20 Nov 2026, 13:30 GST, under sign-in Sample quality manager, by version 1.0.0 of the evidence policy.

VERA's reasonEvery mandatory check passed, and the cautious estimate of how often VERA's output agrees with the expected result meets the policy's limit for restricted, monitored use.

Mandatory checks of the software: 11 of 11 passed
  • The analyser's original file is sealed before anything converts or reads it. Passed.
  • The converted copy agrees with the original file, with nothing lost. Passed.
  • The sample, the run, the analyser, the operator, the reagent lot and every file are identified. Passed.
  • The versions of the software, the models, the references, the methods and the settings are fixed. Passed.
  • Legal approval covers exactly how the software is packaged, where it runs, who uses it and how it runs. Passed.
  • The build is signed, and its signature and origin are checked against the approved signer. Passed.
  • The list of every component in the build is present and genuine, was scanned for known faults, and belongs to this exact build. Passed.
  • The security review passed: the threats considered, known faults, secrets, the network and the controls while running. Passed.
  • The approved test files pass: positive, negative, at the limits, and files that must fail. Passed.
  • The intended clinical or research use is approved in writing. Passed.
  • Going back to the earlier build, withdrawing this build and repeating a result have each been shown. Passed.

The campaign is closed and takes no further record, so this page asks for no new score.

Step 4 The approval

Waiting for the laboratory director

Who: Given by the laboratory director, and by nobody else.

The evidence decision is a score. The approval is the laboratory director's own act: it names the evidence decision it approves, and only then may a clinical result measured in this scope be released.

No approval is recorded for this campaign.

What ends an approved scope

Today a clinical result of this analyser and assay protocol would not pass the scope check on this copy of VERA.

What VERA's scope check says today
  • No campaign approved by the laboratory director covers this analyser and assay protocol (Clinical chemistry, version 1).
  • A changed clinical table

    The scope names every clinical table by the digest of its content, so a copy on which one value of one table has changed is outside the scope until a campaign for the new content is approved.

  • A new build

    The scope names one numbered release and the two parts of the software built from it (the platform, and the worker that runs the pipelines), so a copy that runs any other release or any other build of a part is outside the scope until a campaign for that build is approved.

  • A withdrawal

    The laboratory director may withdraw the approval at any time, and it ends at once, also for a release already being prepared.

  • A later rejection

    When a later campaign of the same scope ends with the decision that the evidence is not sufficient, the earlier approval ends with it.

About this sample campaign

Demonstration

This copy of VERA is an open demonstration. This campaign is a sample: invented records and three invented members of staff, read, scored and compared by the code a laboratory's own VERA runs. The analysers, the clinical tables and their digests are this copy's own.

Two steps need signed-in people: the evidence decision (the quality manager or the laboratory director) and the approval of the scope (the laboratory director).

On this copy each step on this page can be tried as one of the invented members of staff (the sample laboratory scientist, the sample quality manager, the sample laboratory director). The answer comes from the same checks and the same scoring as on a laboratory's own VERA. What is tried is held in the page, sent with each step, and gone on leaving it.

On a laboratory's own VERA the approval is also checked against the signed staff register.

Who takes each step, and why nobody else may

  • Recording the evidence

    A quality manager, laboratory scientist or laboratory director, each signed in.

    Each record is one test file run by one operator on one reagent lot at one site. The same record entered twice is refused, and it is scored once.

  • The evidence decision

    The quality manager or laboratory director, signed in.

    Nobody types the decision in: VERA scores the records under the evidence policy and records the score with its reason. Any other sign-in is refused, and so is a request with no sign-in.

  • Approving the scope

    The laboratory director only, signed in and listed in the signed staff register, with a licence number, as valid on the day.

    The quality manager cannot approve: the decision is a score, and the approval is the laboratory director's own act. A laboratory director who recorded evidence of the campaign cannot approve it either: a person does not approve tests they performed.

  • Withdrawing an approval

    The laboratory director, signed in.

    A withdrawal names the approval it ends, with a reason. Both stay on record; nothing is changed or deleted.

Demonstration copy