Immutable execution plans

Pipeline registry

Instrument profile, assay version, software digests, ordered dependencies, expected inputs, and controlled outputs.
Top-down view of a white modular automation cell with robot arm
Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.

Your definitions

0

No pipeline definitions in your session yet

Register a definition: its stages are checked, it is pinned by its digest, and it is listed here. New definition

Instrument families
10
Governed lanes
12
Equipment source
7 rows
Release posture
Fail closed
Native captureByte-preserved source
CustodyHash, identity, retention
Open conversionPinned validated build
NormalisationLOINC, UCUM, provenance
Cross-axis bundleEvidence-linked signals
KG releaseIndependent approval

Omics reference stacks

Candidate analytical stacks become executable only after exact builds, references, fixtures, and release gates are approved.

PREPAIRE-OMICS-REFERENCE-STACK-REGISTRY@1.0.0
Ready for the laboratory's validation

Short-read germline whole-genome sequencing

Replayable germline SNV, indel, CNV, structural-variant, repeat, carrier, hereditary cancer, secondary-finding, PGx-input, and informational evidence from Element AVITI or MGI DNBSEQ short reads.

Candidate layer: NVIDIA Parabricks deepvariant_germline · Manta · GATK germline CNV workflow

6 stages · 6 blocking gates
Ready for the laboratory's validation

PacBio HiFi germline whole-genome sequencing

Long-read germline small variants, structural variants, tandem repeats, phasing, and native methylation evidence from the IRENA Revio lane.

Candidate layer: PacBio HiFi-human-WGS-WDL · PacBio Jasmine and MethBat · Ensembl VEP

4 stages · 4 blocking gates
Qualification required

Oxford Nanopore germline whole-genome sequencing

PromethION long-read germline SNV, structural-variant, CNV, STR, phasing, and modified-base evidence with exact basecalling model provenance.

Candidate layer: Dorado · EPI2ME wf-human-variation · Ensembl VEP

4 stages · 5 blocking gates
Ready for the laboratory's validation

Shotgun metagenomics

Control-gated stool shotgun taxonomic and functional profiling with separate read-based, AMR, and research assembly products.

Candidate layer: KneadData · MetaPhlAn · HUMAnN

6 stages · 7 blocking gates
Qualification required

Pharmacogenomics

Gene-aware star-allele and high-risk pharmacogenomic interpretation from WGS, retaining PharmCAT as the guideline layer and qualifying specialised upstream callers by gene and platform.

Candidate layer: Aldy 4 · StellarPGx · PharmCAT

3 stages · 4 blocking gates
Assay contract required

Methylation assay router

Route array, bisulfite or enzymatic sequencing, PacBio native, or nanopore modified-base evidence into the correct validated measurement pipeline before any biological-age model is selected.

Candidate layer: SeSAMe or minfi · nf-core/methylseq · Jasmine and MethBat

3 stages · 4 blocking gates
Assay contract required

Illumina iScan genotyping and methylation arrays

Preserve paired iScan IDAT intensity evidence and route each BeadChip through a separately validated genotyping or methylation-array branch.

Candidate layer: SeSAMe

3 stages · 5 blocking gates
Qualification required

Roche cobas pure clinical chemistry and immunoassay

Capture the original cobas pure host result, QC and calibration evidence and normalise approved AXIOM chemistry and immunoassay measurements without altering the regulated source result.

Candidate layer: Assay contract pending

3 stages · 5 blocking gates
Interface contract required

Roche cobas i 601 clinical mass spectrometry

Capture and normalise validated Ionify assay results from the cobas i 601 while preserving calibration, internal-standard, QC, reagent and any supported native LC-MS evidence.

Candidate layer: Assay contract pending

3 stages · 5 blocking gates
Interface contract required

Sysmex XR-1000 haematology

Capture comprehensive CBC, differential, reticulocyte, platelet, body-fluid, flags, QC and supported extended analyser evidence from the XR-1000 for deterministic normalisation and governed release.

Candidate layer: Assay contract pending

3 stages · 5 blocking gates
Interface contract required

Sysmex urine line (U-WAM: UC-3500, UF-5000, UD-10)

Capture chemistry, particle, sediment, flags, images or scattergrams, QC and audit evidence from the installed urine line (UC-3500, UF-5000 and UD-10 through U-WAM), each result attributed to the module that reported it.

Candidate layer: Assay contract pending

3 stages · 5 blocking gates
Method contract required

Organic-acid mass spectrometry

Preserve vendor-native chromatography and mass-spectrometry evidence, convert to open mzML, and qualify targeted quantitative organic-acid analysis independently of a PDF report.

Candidate layer: MZmine 4

3 stages · 4 blocking gates

Demonstration copy