Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.
Your definitions
0
No pipeline definitions in your session yet
Register a definition: its stages are checked, it is pinned by its digest, and it is listed here. New definition
Instrument families
10
Governed lanes
12
Equipment source
7 rows
Release posture
Fail closed
Native captureByte-preserved source
CustodyHash, identity, retention
Open conversionPinned validated build
NormalisationLOINC, UCUM, provenance
Cross-axis bundleEvidence-linked signals
KG releaseIndependent approval
Omics reference stacks
Candidate analytical stacks become executable only after exact builds, references, fixtures, and release gates are approved.
PREPAIRE-OMICS-REFERENCE-STACK-REGISTRY@1.0.0
Ready for the laboratory's validation
Short-read germline whole-genome sequencing
Replayable germline SNV, indel, CNV, structural-variant, repeat, carrier, hereditary cancer, secondary-finding, PGx-input, and informational evidence from Element AVITI or MGI DNBSEQ short reads.
Control-gated stool shotgun taxonomic and functional profiling with separate read-based, AMR, and research assembly products.
Candidate layer: KneadData · MetaPhlAn · HUMAnN
6 stages · 7 blocking gates
Qualification required
Pharmacogenomics
Gene-aware star-allele and high-risk pharmacogenomic interpretation from WGS, retaining PharmCAT as the guideline layer and qualifying specialised upstream callers by gene and platform.
Candidate layer: Aldy 4 · StellarPGx · PharmCAT
3 stages · 4 blocking gates
Assay contract required
Methylation assay router
Route array, bisulfite or enzymatic sequencing, PacBio native, or nanopore modified-base evidence into the correct validated measurement pipeline before any biological-age model is selected.
Candidate layer: SeSAMe or minfi · nf-core/methylseq · Jasmine and MethBat
3 stages · 4 blocking gates
Assay contract required
Illumina iScan genotyping and methylation arrays
Preserve paired iScan IDAT intensity evidence and route each BeadChip through a separately validated genotyping or methylation-array branch.
Candidate layer: SeSAMe
3 stages · 5 blocking gates
Qualification required
Roche cobas pure clinical chemistry and immunoassay
Capture the original cobas pure host result, QC and calibration evidence and normalise approved AXIOM chemistry and immunoassay measurements without altering the regulated source result.
Candidate layer: Assay contract pending
3 stages · 5 blocking gates
Interface contract required
Roche cobas i 601 clinical mass spectrometry
Capture and normalise validated Ionify assay results from the cobas i 601 while preserving calibration, internal-standard, QC, reagent and any supported native LC-MS evidence.
Candidate layer: Assay contract pending
3 stages · 5 blocking gates
Interface contract required
Sysmex XR-1000 haematology
Capture comprehensive CBC, differential, reticulocyte, platelet, body-fluid, flags, QC and supported extended analyser evidence from the XR-1000 for deterministic normalisation and governed release.
Candidate layer: Assay contract pending
3 stages · 5 blocking gates
Interface contract required
Sysmex urine line (U-WAM: UC-3500, UF-5000, UD-10)
Capture chemistry, particle, sediment, flags, images or scattergrams, QC and audit evidence from the installed urine line (UC-3500, UF-5000 and UD-10 through U-WAM), each result attributed to the module that reported it.
Candidate layer: Assay contract pending
3 stages · 5 blocking gates
Method contract required
Organic-acid mass spectrometry
Preserve vendor-native chromatography and mass-spectrometry evidence, convert to open mzML, and qualify targeted quantitative organic-acid analysis independently of a PDF report.