VERA by Prepaire / Help
About & help

How a machine file becomes evidence
The release sequence, explained
Keep the original
Collect the earliest supported evidence from the instrument. Keep it unchanged, together with the information needed to understand it.
Your part
Follow the approved extraction instructions for that exact machine and test.
The safeguard
A report or a converted file must not silently replace the original evidence.
Extraction playbooksIf a required check fails, the evidence stays on hold. There is no automatic bypass.
Try it yourself
Your first run, in five steps
- 01Start here
See why each organ has its own age
Organ age: each organ's own age, from the proteins in a blood sample, followed from the person's first sample.
Open organ age - 02You, in the browser
Bring in old reports
Read a sample person's old lab reports. Click any value to see the line it was printed on, then confirm them into the person's own knowledge graph.
Import the old reports - 03You, as the pathologist
Run a sample
Pick a person and an analyser and press Run. VERA takes the sample through every check; you approve and release it, then open that person's twin.
Run a sample - 04You, in the browser
See a sample person's knowledge graph
The chosen person's results in an encrypted graph of the person's own, beside VERA's reference graph of public science, kept apart.
Open the person's graph - 05You, in the browser
Drop a DNA file
Drop a FASTQ file of DNA reads: VERA checks every read inside your browser and shows what it found.
Read a FASTQ file
Who does what
- 01Administrator + laboratory lead
Check that the workspace is ready
An administrator connects the operational services and sign-in system. The laboratory approves the instrument and test. Read-only mode lets you inspect the app; laboratory actions open once the services and the sign-in system are connected and the laboratory has approved the instrument and test.
Check settings - 02Laboratory operator
Match the sample to the machine
Use the laboratory-issued sample code and the correct physical instrument. Check the extraction instructions for that machine. Stop and ask the laboratory lead if anything does not match.
Find the instrument - 03Authorised laboratory operator
Create the run and capture evidence
Create a controlled ingestion run for an eligible instrument and test. In the run, add the approved source evidence and seal it for verification. Large files require the streaming edge-capture path in the operating handbook.
New ingestion - 04Technical team + operator
Follow the approved processing plan
Technical staff prepare the exact software builds and pipeline. Follow the run's verification and execution state. The Analysis upload is for structured JSON evidence packages, not raw machine files.
Review analysis - 05Independent authorised reviewer
Obtain independent release approval
A separate authorised reviewer checks the evidence and required approvals. An upload or structure-validation result is not permission to release. Unresolved required checks keep the evidence on hold.
Open release ledger
When something is unclear
Common questions
Why is a button disabled?
The action may require a connected database, verified sign-in, an approved instrument/test combination, or approved software. Read the requirement beside the action. Your technical administrator handles connections; the laboratory lead and independent reviewer handle the relevant approvals. Do not work around a disabled control.
Can I upload a PDF, spreadsheet or sequencing file anywhere?
Yes, in three places: old PDF reports on Import, a FASTQ file on Sequencing reads, and an instrument file on VERA for the lab. On a real run, raw instrument files go through the controlled capture path for the file type and machine profile; a report is kept as a report and never replaces the native evidence.
Does normalisation tell me whether a result is healthy?
No. Normalisation gives a result consistent names, units and structure. Clinical interpretation, reference-range selection and patient advice require validated methods, adequate evidence and the appropriate professional review.
Which of the listed analysis tools run today?
VERA's own code runs today: it reads analyser result messages, FASTQ files and old reports, and computes each person's own ranges. The reference stacks list, for each stage, the tools chosen as candidates and the tools they are compared with. A listed tool becomes a pipeline that runs when its exact build, licence, reference set, instrument configuration and assay have the required approvals.
What should I do about a wrong sample code or unit?
Stop the affected workflow and escalate to the laboratory lead. Keep the original evidence and document the issue. Do not guess, overwrite the original or change a label simply to pass validation. Follow the controlled correction process in the operating handbook.
Is this a patient-facing medical report?
No. VERA is a laboratory evidence platform. A released graph package supplies traceable evidence to downstream systems. It does not, by itself, diagnose disease, prove causality or authorise a treatment recommendation.
No specialist vocabulary required
In plain language
14 terms
- Raw / native data
- The earliest supported machine evidence available to the capture workflow, before downstream reporting or interpretation.
- Ingestion
- Bringing a file and its identifying information into VERA under controlled checks.
- Sample reference
- A laboratory-issued code for the biological sample. It is not the person's name, email address or phone number.
- Assay
- The laboratory test being performed. Its approved protocol and version define how it should be run.
- Pipeline
- An ordered, version-controlled set of software steps for a particular machine and test.
- Hash / digital fingerprint
- A value calculated from a file to help detect changes. It checks file integrity, not whether the sample belongs to the right person.
- Normalisation
- Representing measurements with consistent names, codes, units and context. This is different from deciding whether a result is clinically normal.
- Provenance / custody
- The record of where evidence came from, who handled it, and which processing steps produced each output.
- JSON evidence package
- A structured text file with named fields and values. Technical staff prepare it to match VERA's evidence contract; it is not a raw sequencing file.
- Knowledge graph / KG
- A structured network of biological facts and their relationships, with links back to supporting evidence.
- Cross-axis
- Looking at relationships across biological systems, such as the gut and immune system. An association is not automatically a cause.
- Blocked / on hold
- A required condition has not been met. The responsible operator, technical administrator or independent reviewer must resolve it before proceeding.
- Read-only workspace
- You can inspect the interface and registry; operational actions open once services, identity and required approvals are in place.
- Release
- The independently approved transfer of a verified evidence package into the graph. Uploading, validating structure and releasing are different actions.