Ingestion runs

Controlled custody

New ingestion run

Bind a tube to a governed analyser and its released test, then run it: VERA captures the analyser’s message, checks it and queues the results for review. Below the run, each analyser line is checked against the run policy, as the lab checks it before a real run.
Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.

Start the run

Sample data

Pick the person and the analyser, then press Run. The analyser's message is captured by the read-only listener, checked, quality-controlled and queued for the pathologist by the same code as every run. Approve it here, or later on the release ledger.

1Person

2Analyser

Choose whose sample to run.

  1. 1Order and tube
  2. 2Before the analyser
  3. 3The analyser sends its results
  4. 4VERA captures a copy
  5. 5Results read and checked
  6. 6Mapped to the national code list
  7. 7Quality control
  8. 8Safety checks and personal ranges
  9. 9Pathologist review
  10. 10Released
  11. 11Signed lab report
  12. 12Message for the clinic’s system, not sent
  13. 13Message for Malaffi, not sent
  14. 14Knowledge graph
  15. 15Personal ranges

Sample data: Sarah, Mariam, Daniel and the staff named here are invented, and every report is marked Sample. Where a rule table still waits for the laboratory director’s signature, a labelled demonstration sign-off stands in for these samples only; it can never apply to a real patient. A sample run sends nothing anywhere. Each run: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk. You can clear it at any time.

Governed instruments

4 analyser lines
  • Sysmex XR-1000 · Full blood count

    Awaiting activation at IRENA. On real data VERA refuses a run on it today, because:

    • Its connection to VERA is not qualified yet: its connection is still to be set up on site.
    • The IPU software version is not recorded: read it from the IPU.
    • The serial number is in the asset list of 17 Nov 2026.
    • Its control computer must be set to send results in the standard laboratory format (ASTM), not Sysmex's own.

    A synthetic sample still runs above, on the demonstration sign-off, and each stage says what real data meets today. Record a site approval

  • Sysmex urine line · Urine test (chemistry, cells, images) · Sysmex UC-3500

    Awaiting activation at IRENA. On real data VERA refuses a run on it today, because:

    • Its connection to VERA is not qualified yet: its connection is still to be set up on site.
    • The version of its control software (U-WAM) is not recorded yet.
    • Sysmex's specification for its connection is not yet in hand.
    • No current approval from the quality manager.

    A synthetic sample still runs above, on the demonstration sign-off, and each stage says what real data meets today. Record a site approval

  • cobas c 303 · Clinical chemistry · Roche cobas pure (c 303 + e 402)

    Awaiting activation at IRENA. On real data VERA refuses a run on it today, because:

    • Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
    • Roche's guide to its connection, its installed versions and the fields it sends are not yet in hand.
    • Raw detector signals are not assumed to be available through the host interface.
    • No current approval from the quality manager.

    A synthetic sample still runs above, on the demonstration sign-off, and each stage says what real data meets today. Record a site approval

  • cobas e 402 · Hormones and vitamins · Roche cobas pure (c 303 + e 402)

    Awaiting activation at IRENA. On real data VERA refuses a run on it today, because:

    • Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
    • Roche's guide to its connection, its installed versions and the fields it sends are not yet in hand.
    • Raw detector signals are not assumed to be available through the host interface.
    • No current approval from the quality manager.

    A synthetic sample still runs above, on the demonstration sign-off, and each stage says what real data meets today. Record a site approval

Demonstration copy