Robot and liquid-handler logs

What each robot did to each tube, read by VERA from its log

The robots and liquid handlers at IRENA move tubes, pipette blood and DNA into plates, and write down every step in a log. VERA reads such a log line by line: when, which machine, what it did, whether it went wrong, and which tube and plate each line names. It follows every tube to the plate and well it went to, and says plainly where a step failed or a tube could not be identified.
  1. 1 · One step per lineHamilton trace files, Fairino and Epson robot logs, and MGI liquid-handler tables, read into the same kind of step.
  2. 2 · Follows each tubeA dispense names only where the liquid went, so VERA carries the tube each pipetting channel took up to its next dispense.
  3. 3 · Holds what went wrongAn error holds the samples it touched; a run that never ended, or a well filled from a tube nobody could identify, holds too.

Read a log

Sample logs

Made by VERA for this page in each machine's shape: invented tubes in IRENA's label format, invented plates and racks. No machine wrote them.

  • Sample Hamilton STARlet EasyBlood, blood fractionation
    Three tubes split into plasma and buffy coat plates
  • Sample Hamilton Microlab STAR, DNA normalisation
    DNA from three wells moved into a library plate
  • Sample Fairino FR5 cobot, pass box to centrifuge
    Three tubes scanned, picked and placed in the centrifuge rack
  • Sample Epson C8 robot, tubes to a library plate
    Three tubes moved from a rack to plate wells
  • Sample MGISP-960, DNA extraction
    Three samples transferred to an extraction plate, lysis buffer added

Or a log file on this computer

A Hamilton .trc trace, a Fairino or Epson log, or an MGI table (.csv or .tsv), up to 8 MB. Read in this browser; nothing is uploaded.

What VERA read

Hamilton VENUS trace file from Hamilton Blood Fractionation (SRA-HBF-000001), Sample Receiving Area. From 07:41 GST to 07:45 GST, 12 Nov 2026. Every step is read, and nothing went wrong.

Lines
18
Step events
26
Samples
3
Plates and racks
2
Errors
0
Warnings
0
  • As it should beRead as a Hamilton VENUS trace file: 18 lines, 26 step events.
  • As it should beNo step reported an error.
  • As it should beEvery step that started also ended.
  • As it should be3 samples named; 3 followed to a plate or rack position.
  • Noted10 step events name no sample and no plate (moves, tips, start and end): kept as steps of the run.

Each tube, followed

Each sample and where it went
TubeWent toStepsFirstLastErrors
IRN261112011PLT-261112-01 A1PLT-261112-02 A1507:41 GST07:44 GSTNone
IRN261112012PLT-261112-01 B1PLT-261112-02 B1507:41 GST07:44 GSTNone
IRN261112013PLT-261112-01 C1PLT-261112-02 C1507:41 GST07:44 GSTNone

Plates and racks

Plates and racks the log names
Plate or rackTubes in itWells and positionsSteps
PLT-261112-01IRN261112011, IRN261112012, IRN261112013A1, B1, C14
PLT-261112-02IRN261112011, IRN261112012, IRN261112013A1, B1, C14

Every step

Step events
LineTimeStepTubesPlate or rackWellVolumeDetails
107:41 GSTExecute method (start)NoneNoneNoneNoneMethod file EasyBlood_Fractionation.hsl (synthetic)
207:41 GSTInitialize (start)NoneNoneNoneNone
307:41 GSTInitialize (end)NoneNoneNoneNone
407:41 GSTLoad Carrier (start)NoneNoneNoneNoneCarrier SMP_CAR_24_0001
507:41 GSTLoad CarrierIRN261112011None1Noneposition 1: tube IRN261112011
607:41 GSTLoad CarrierIRN261112012None2Noneposition 2: tube IRN261112012
707:41 GSTLoad CarrierIRN261112013None3Noneposition 3: tube IRN261112013
807:42 GSTLoad Carrier (end)NoneNoneNoneNoneCarrier SMP_CAR_24_0001, 3 tubes
907:42 GSTLoad Carrier (end)NonePLT-261112-01, PLT-261112-02NoneNoneCarrier PLT_CAR_L5_0001: plate PLT-261112-01 (plasma), plate PLT-261112-02 (buffy coat)
1007:42 GSTTip Pick Up (end)NoneNoneNoneNonechannel 1: TIPS_1000_0001, A1; channel 2: TIPS_1000_0001, B1; channel 3: TIPS_1000_0001, C1
1107:43 GSTAspirate (end)IRN261112011NoneNone1,500 µLchannel 1: tube IRN261112011, 1500 uL
1107:43 GSTAspirate (end)IRN261112012NoneNone1,500 µLchannel 2: tube IRN261112012, 1500 uL
1107:43 GSTAspirate (end)IRN261112013NoneNone1,500 µLchannel 3: tube IRN261112013, 1500 uL
1207:43 GSTDispense (end)IRN261112011 taken up at line 11PLT-261112-01A11,500 µLchannel 1: plate PLT-261112-01, well A1, 1500 uL
1207:43 GSTDispense (end)IRN261112013 taken up at line 11PLT-261112-01C11,500 µLchannel 3: plate PLT-261112-01, well C1, 1500 uL
1207:43 GSTDispense (end)IRN261112012 taken up at line 11PLT-261112-01B11,500 µLchannel 2: plate PLT-261112-01, well B1, 1500 uL
1307:43 GSTTip Eject (end)NoneNoneNoneNonechannel 1, 2, 3: waste
1407:44 GSTTip Pick Up (end)NoneNoneNoneNonechannel 1: TIPS_300_0001, A1; channel 2: TIPS_300_0001, B1; channel 3: TIPS_300_0001, C1
1507:44 GSTAspirate (end)IRN261112011NoneNone250 µLchannel 1: tube IRN261112011, 250 uL
1507:44 GSTAspirate (end)IRN261112012NoneNone250 µLchannel 2: tube IRN261112012, 250 uL
1507:44 GSTAspirate (end)IRN261112013NoneNone250 µLchannel 3: tube IRN261112013, 250 uL
1607:44 GSTDispense (end)IRN261112011 taken up at line 15PLT-261112-02A1250 µLchannel 1: plate PLT-261112-02, well A1, 250 uL
1607:44 GSTDispense (end)IRN261112012 taken up at line 15PLT-261112-02B1250 µLchannel 2: plate PLT-261112-02, well B1, 250 uL
1607:44 GSTDispense (end)IRN261112013 taken up at line 15PLT-261112-02C1250 µLchannel 3: plate PLT-261112-02, well C1, 250 uL
1707:45 GSTTip Eject (end)NoneNoneNoneNonechannel 1, 2, 3: waste
1807:45 GSTExecute method (end)NoneNoneNoneNone3 tubes fractionated

Demonstration copy