From the standard range to a personal range
The personalisation staircase
S0 → S4
Five stages, each reached only with enough data
S0 Standard ranges
863 cited standard ranges across 98 analytes from ARUP, NHANES, NORIP and guideline bodies; every row carries its citation.
Built, in the reference graphStatus: In another Prepaire systemRequires: Nothing: ships today
S1 Stratified + genotype
Sex, age and condition today; variant-keyed tomorrow (ACKR1 Duffy-null, APOL1 kidney risk).
Structure built; genotype axis waits for the WGS laneStatus: In another Prepaire systemRequires: WGS lane live, so the genotype axis can populate
S2 Personal baseline
A person's own range starts once VERA has four of their results that agree: from the fifth result on, each new one is read against it. The twin flags a departure from the person's own range, beside the standard range.
Built: VERA's personal-range engine computes the person's own range from their drawsStatus: Live in this appRequires: Four draws of the same test through a validated lane
S3 Cross-omic evidence
Models correlate microbiome × metabolome × CBC × genome. Outputs are Tier-2 evidence, never merged into Tier 1.
When multi-omic data flowsStatus: PlannedRequires: Blood, WGS and stool lanes flowing; the two-tier boundary holds absolutely
S4 Prepaire cohort ranges
Aggregate ranges from Gulf, South Asian, African and European participants, measured on Prepaire's own instruments.
Long termStatus: PlannedRequires: Hundreds of participants per stratum through AXIOM
Naming note. This page uses the framework document's wording. In VERA's own words the same ladder is S0 the standard range, S1 conditioned cohort, S2 provisional personal baseline, S3 established personal homeostatic band, S4 personal target. Today VERA computes S2, the person's own range, from their results (below, on this page).
Personal baseline · S2
The person's own ApoB range, computed on this page
ApoB, a carrier of cholesterol in the blood, from the sample person's draws. VERA learns the person's own range from their draws and reads each new draw against it. Change a value, add a draw or take one away, and the range moves.
The latest draw
110 mg/dL
Above their range: a real change for them
- The own range it was read againstfrom 5 of the person's 5 earlier draws
- 65–88
- The range now, for the next drawfrom 5 of the person's 6 draws
- 65–88
- The standard range
- 60–130 mg/dL
- The usual level
- 76
- From the usual level
- +45%
- The everyday swing
- −18% to +21%
- Since the previous draw
- +47%
A draw is a real change for the person only when it moves further from their usual level than their everyday swing.
Not counted in the range now: 1 of the person's 6 draws
- 30 Sep 2026, 110 mg/dL: 46% above the level of their other 5 draws: VERA learns their usual level only from draws within 16% of the others. It is a real change for the person, so it waits outside their usual level until their next draws show whether it is their new level.
The 6 draws: change one, add one, take one away
- 1
- 2
- 3
- 4
- 5
- 6
Computed now, on this page. VERA's personal-range engine (the one Import and Run a sample use) learns the person's range from the draws above each time you change them. It uses the published within-person variation for ApoB, 6.3% (EFLM, awaiting the laboratory director's sign-off), and the laboratory's measurement imprecision, a sample figure of half that, 3.1%, until a laboratory enters its own.
Safety rails
A personalised interval can never silently clear a published diagnostic criterion (ReferenceRange and DiagnosticCriterion are separate node types by design).
A current measurement outranks a genetic potential: the risk stays on record; the reading governs today.
For markers with strong dose-dependent causal evidence (ApoB, LDL, BP, HbA1c, tobacco), personalisation refines interpretation but never declares a high value harmless because it is stable for the individual.
Laboratory side
Reference and benchmark cohorts
The reference and benchmark cohorts on Prepaire's register, each with its state.
Reference and benchmark cohort; Prepaire's access is active.
Planned reference cohort.
The S0 corpus already stands on ARUP, NHANES and NORIP; a GMRepo adapter is planned as the microbiome cohort axis; and Prepaire's own AXIOM cohort is to grow with each participant the lanes take.