Every station is worked out now by VERA’s own code: the order, the analyser’s message, the read-only copy, the checks, the approvals and the person’s own record. It takes a few seconds.
Loading the sample journey.
Sample journey
Mariam's sample, station by station
Sample run through VERA's pipeline
Eleven stations, from the tube to the person's own record. Each one shows what VERA’s own code did at that step to this sample, in the run below.
Mariam on the cobas c 303
Waiting for release
Clinical chemistry
Tube IRN261129031
Serum
Run at 17:04 GST
VERA worked this run out at 17:28 GST, in 202 ms of its own code, and keeps it up to 30 minutes in memory for anyone who opens the same run
This is the run its link names. VERA could not confirm a release for it, so the journey stops at the pathologist's review: nothing of it is released here.
Mariam's order is checked: from a licensed clinician, with consents on file. The tube is labelled and received.
Received 08:45 GST · the demonstration laboratory scientist
For
Mariam, 34
Ordered by
Dr Demonstration Clinician, checked against the Department of Health register
Consents
Collection and data sharing, on approved forms
Name in VERA
never stored: VERA knows Mariam only by a code
Tube
Serum separator tube, labelled IRN261129031
The order rules await the laboratory director's signature: on real data VERA refuses the order today because the order rules are not signed yet. Here a demonstration sign-off stands in, for this synthetic sample only.
At IRENA the order comes from the laboratory's own system for a real patient; here VERA makes a sample order for an invented person.
The cobas c 303 measures the tube and sends 22 results to the laboratory system, as it does every day. VERA's code took 1 ms here.
Zone 2
At the analyser
The results become data, and VERA keeps a copy.
04
VERA™ takes a read-only copy
DoneVERA’s code: 187 ms
RenderVERA Edge enclosure with an NVIDIA DGX Spark, as designed
VERA copied the machine's results without touching the machine: it listens, and never sends anything back.
Copied
all 5,356 bytes; sent nothing back: 0 bytes to the analyser
Listen-only
the part that could send anything was removed before the first byte arrived
The analyser's question
recorded and never answered: the laboratory system answers it
Kept in
a fresh database made for this run alone, closed when the run ends
On Prepaire's own computer VERA's read-only listener takes this copy from a mirror of the analyser's link, once it is switched on for that analyser; here the copy travels inside this one server.
VERA copied the machine's results without touching the machine: it listens, and never sends anything back. VERA's code took 187 ms here.
Zone 3
Sealed and kept at home
Encrypted before anything moves, and kept where it belongs.
05
Sealed and fingerprinted
Done
Before anything moves, VERA sealed the copy (2 messages) under a key made for this run and fingerprinted it; its 3 entries are chained one to the next, with no break.
Sealed
2 messages, encrypted (AES-256) under a key made for this run
Fingerprint
4f61e8f39195… (of everything copied: change a single byte and the fingerprint changes)
Chain
3 entries, each linked to the one before: no break; re-read byte for byte
At IRENA the sealed copy then crosses the encrypted network by Nokia to the laboratory's own data centre; here everything stays on one server.
Before anything moves, VERA sealed the copy (2 messages) under a key made for this run and fingerprinted it; its 3 entries are chained one to the next, with no break.
06
Where the data may go
Done
The rule asks what kind of data it is and where it would go, never whose it is: anyone's cobas c 303 message gets the same answer.
The cobas c 303's own message, as VERA copied it5,356 bytes, sealed at station 05
On this siteAllowedTo the DGX Spark task service. The engine runs on this site, so the data stays here.
In a cloudRefusedTo the GPU pipeline server. An instrument's own signal never leaves the site. No pseudonymisation is recorded on this data, and VERA never assumes it. No legal approver has assessed sending this kind of data to this engine in a cloud.
Mariam's 22 results, once releasedthe results and the trail back to their evidence
On this siteAllowedTo the DGX Spark task service. The engine runs on this site, so the data stays here.
In a cloudRefusedTo the GPU pipeline server. Released results and the trails back to their evidence never leave the site. No pseudonymisation is recorded on this data, and VERA never assumes it. No legal approver has assessed sending this kind of data to this engine in a cloud.
The rule asks what kind of data it is and where it would go, never whose it is: anyone's cobas c 303 message gets the same answer.
On Prepaire's own computer the same rule runs before every call to an analysis engine, and reads a legal approver's signed assessment where one is on record.
The rule asks what kind of data it is and where it would go, never whose it is: anyone's cobas c 303 message gets the same answer.
Zone 4
Checked
Read, coded and checked, result by result.
07
Read and coded
DoneVERA’s code: 2 ms
22 results read from the sealed copy, each matched to the right tube and person.
Every result mapped to the national code list, in one standard unit.
Tube
IRN261129031, matched to the specimen record
Result of the checks
ready for review (1 note for the pathologist)
Identity
VERA never reads Mariam's name or ID number from the message: only Mariam's code and the tube
Checked
every part of the message and its check digits, the order of the records, the tube and the specimen type
Test menu
Prepaire's test menu, 129 tests
Coded
each result to its national code (LOINC), for example Glucose (fasting) → 1558-6
Units
Calcium: 2.37 mmol/L → 9.5 mg/dL
On real data today the gate quarantines this message: the GenetiQ Check catalogue and code map awaits the laboratory director's signature. The demonstration sign-off applies to this synthetic sample only.
22 results read from the sealed copy, each matched to the right tube and person. Every result mapped to the national code list, in one standard unit. VERA's code took 2 ms here.
08
Quality control and Mariam's own ranges
DoneVERA’s code: 3 ms
Every test is in control on cobas c 303: 22 results, controls checked by VERA itself.
Nothing dangerous, nothing unexpected. 22 results read against Mariam's own range: no real change.
Control rules
the standard Westgard rules: a small drift warns, a large one or a pattern stops the run
Controls
two levels every 8 h; the last run 16:31 GST, 30 min before the sample
Calibration
accepted 3 days ago, valid 30 days (the demonstration interval)
Records
captured by each analyser from a message VERA stored, within 10 minutes; none entered by hand
Danger limits
5 rules: none reached
Change since last time
against the last result (40 days ago): no unexpected change
Own ranges
22 results with a personal range from 4 earlier tests
Identity
tube, vial, order and subject agree; specimen type matches every marker
On real data today QC is not evaluable: the QC rules and control targets await the laboratory director's signature. Demonstration targets and a synthetic control history stand in.
Every test is in control on cobas c 303: 22 results, controls checked by VERA itself. Nothing dangerous, nothing unexpected. 22 results read against Mariam's own range: no real change. VERA's code took 3 ms here.
Zone 5
Approved by people
Nothing leaves VERA until two people have signed.
09
The pathologist approves, a second person releases
Waiting for the pathologistVERA’s code: 1 ms
22 results wait for the pathologist. Nothing leaves VERA until a person approves each one.
Reviewer
a pathologist who is not a submitter of the run
The demonstration reviewer approves in the synthetic lane only. On real data the pathologist signs in with their own account and approves each result.
On Prepaire's own computer a signed report's message goes to the hospital its order came from, once that hospital's address is listed and the information security officer has approved it. The outbox sends a release's message to Malaffi once; a send needs the Malaffi tables signed and Malaffi's connection details set on the copy that sends.
On Prepaire's own computer the graph is kept, sealed under the person's own key, and grows with every visit; here it is built in this server's memory for this run, kept up to 30 minutes and never written to disk.
Sample data: the people, the staff and the orders on this page are invented, and every report is marked Sample. Where a rule table still waits for the laboratory director’s signature, a labelled demonstration sign-off stands in for these samples only; it can never apply to a real patient. A sample run sends nothing anywhere, and this copy remembers your last run for 30 minutes in this server’s memory only. Times are Gulf Standard Time (GST, UTC+4).