Simulated deck your own copy for 30 minutes
The IRENA gantry link is simulated. Runs, wells, incubator readings and sidecar jobs come from the CellOS simulation of the locked SOPs; the workcell photographs are of the real Masdar deck, and the others are Prepaire brand photography. Research use only. Not a medical device. Not a clinical release system.
Your own deck. Its clock runs and every control works on it, for you alone. It is held in memory only, never stored, and clears 30 minutes after you close this page, or when you start over.
Safety
Residual iPSC control

Status: Simulated dataDual-control rehearsal. The enclosed TRA-1-60 laser package is planned (gap G.13, deferred) and the iCasp9 switch is a property of an engineered bank. Here both signature buttons sit on one screen so you can play both people; on the deck each person signs in separately.
- 1
Claim language
No detectable residual undifferentiated iPSCs above the validated assay limit. Absolute “100% teratoma-free” is not a release claim.
- 2
Dye gate
TRA-1-60 live stain flags targets. Phase 1 fluorescence is sacrificial. Image coordinates can drive a later laser; they cannot clear a batch.
- 3
Human authority
Dual arm: the operator and a second signer, two different people. The robot may recommend and hold. It may not discard unique material or fire a kill mechanism alone.
No programme with laser clearance is on your deck. Put “TD-uhiPSC-DC · U266 qualification” on it to rehearse the two-person rule.
Target overlay
Ringed wells carry TRA-1-60-like residual signal. Pick the well to aim at. On the deck: SAT-7 · WTC11 feeder-free cycle
Laser arm
Enclosed laser, written as method SOP-007. Deferred (gap E) until the first acceptance run passes.
- OperatorNot signed
- Second signerNot signed
Try it: sign as one person only and fire. The robot refuses a single signature and writes the refusal to the batch log.
The laser only fires on a programme whose recipe declares laser clearance. Create a programme from the Cell Builder's first brief (TumorDressed DCs with a TRA-1-60 laser gate) and dispatch it to rehearse.
Both kill mechanisms need two distinct armed roles and disarm after use.
Batch log
What the deck wrote for this run, newest first: every pulse, trigger and refusal is recorded.
- 18:42:11 GSTB3 differentiated area 6.0%: advisory hold on autonomous passage.
- 18:42:00 GSTDay 3 image: 5 of 6 wells GREEN; B3 YELLOW (edge merge).
- 09:58:40 GSTDay 2 feed complete.
- 08:12:00 GSTDay 1 whole-well images exported. Mean confluence 28%.
- 08:14:21 GSTVitronectin coating complete · no dry-well flag.
- 08:12:04 GSTRun SAT-7 released. WTC11 P18 identity matched.