Simulated deck your own copy for 30 minutes
The IRENA gantry link is simulated. Runs, wells, incubator readings and sidecar jobs come from the CellOS simulation of the locked SOPs; the workcell photographs are of the real Masdar deck, and the others are Prepaire brand photography. Research use only. Not a medical device. Not a clinical release system.
Your own deck. Its clock runs and every control works on it, for you alone. It is held in memory only, never stored, and clears 30 minutes after you close this page, or when you start over.
Product brochure
CellOS · the IRENA cell engineering OS

ReferenceThe printed brochure of the IRENA workcell, as built. The working deck is under Command, Cell Builder, Runs and Safety.
- 1
Off-the-shelf (allogeneic) therapy
Off-the-shelf therapy comes from a qualified master cell bank. Patient blood and tumour build the test environment, not the manufacturing chassis.
- 2
Every step is recorded
Every coat, seed, feed, image, passage and sidecar job writes an electronic batch record. The robot may recommend. It may not discard unique material alone.
- 3
Residual iPSC control
TRA-1-60 dyes, optional iCasp9 switch, optional enclosed laser. Dual human arm. Orthogonal molecular or flow assay is the release gate — never the camera.
As built
Masdar BSL-3 workcell




Dual gantry liquid handling
Status: As built at IRENAIdentity-safe plate moves, coating, feed, Versene / TrypLE, pellet aspiration. Transport and spin are on the machine today.
NeXCell R automated incubator
Status: As built at IRENAWaken Tech NR-series CO₂ incubator with sliding plate stage, HEPA Class 5, RS-232 / Ethernet. Connected as the environmental sidecar.
Inline optics
Status: Acceptance test awaitedWhole-well brightfield plus fluorescence, robot coordinates, raw OME-TIFF. Highest-priority remaining module — Celigo-class.
Humanoid + NVIDIA Spark
Status: ProposalClosed-room assistant for trolley moves and kit presentation. Onboard inference stays off the sterile gantry path.
Platform
One clone, one bank, then manufacture from a vial
Single-step multiplex gene editing on an iPSC, clonal sort, master cell bank, then manufacture from a vial — the same logic as the Prepaire iPSC platform schematic below. The schematic describes the commercial model for an allogeneic engineered bank. It is not a claim that any therapy exists or is approved.
- 01
Single step multiplex gene editing
Induced pluripotent stem cell (iPSC)
Clonal sorting and selection
× De-selected clones
- 02
Single product candidate clone
iPSC expansion and MCB creation
- 03
Clonal Master Cell Bank (MCB)
Manufactured starting from MCB Vial
- 04
Stored Drug Inventory
- 05
Treat thousands of patients on-demand
System specification
Connected hardware as installed at IRENA, September 2026.
| Site | IRENA BSL-3 · Masdar, Abu Dhabi |
|---|---|
| Enclosure | ISO-style glass isolator, HEPA supply, CCTV |
| Vessels | 6-well, ULA 96, V-bottom 96, T25 / T75 |
| Incubator | NeXCell R NR28/48 class · 37 °C ±0.5 · 5% CO₂ |
| Environment | Temp, CO₂, optional O₂, ultrasonic RH |
| Communications | RS-232 / RS-485, Ethernet, CellOS LAM |
| Identity | Barcode + electronic batch genealogy |
| Release posture | Research use. Not a clinical release system. |
Run the operating system
Open Command, compose a cell programme, and watch the SAT-7 feeder-free cycle on the simulated deck.