CellOSIRENA · cell engineering OSOptics acceptance test awaitedRobot live (simulated)
Sample journey

Simulated deck your own copy for 30 minutes

Product brochure

CellOS · the IRENA cell engineering OS

One process from a bank of stem cells to cells ready for testing, with each person's identity kept safe at every step. Design a programme, translate it onto the BSL-3 robot, and manufacture from a vial of a qualified bank rather than growing a new line of stem cells for every person. Research use only; nothing made on this platform is an approved therapy.
IRENA glass workcell suite

ReferenceThe printed brochure of the IRENA workcell, as built. The working deck is under Command, Cell Builder, Runs and Safety.

  1. 1

    Off-the-shelf (allogeneic) therapy

    Off-the-shelf therapy comes from a qualified master cell bank. Patient blood and tumour build the test environment, not the manufacturing chassis.

  2. 2

    Every step is recorded

    Every coat, seed, feed, image, passage and sidecar job writes an electronic batch record. The robot may recommend. It may not discard unique material alone.

  3. 3

    Residual iPSC control

    TRA-1-60 dyes, optional iCasp9 switch, optional enclosed laser. Dual human arm. Orthogonal molecular or flow assay is the release gate — never the camera.

As built

Masdar BSL-3 workcell

IRENA dual-gantry workcell and NeXCell incubator inside the glass isolator
Dual gantry liquid handlers, plate nests and the NeXCell automated incubator inside the glass envelope.
Incubator and dual gantry inside the IRENA glass isolator
Sliding-stage incubator handoff. Load/unload target is under 25 seconds, matching the NeXCell R series.
Overhead view of the IRENA deck: glass isolator, HEPA ceiling and CCTV
HEPA ceiling, CCTV, and identity-safe plate path from incubator cassette to gantry nest.
Plate deck of the IRENA workcell, with the closed-room humanoid standing by
6-well and 96-well deck with the closed-room humanoid standing by for kit presentation.

Dual gantry liquid handling

Status: As built at IRENA

Identity-safe plate moves, coating, feed, Versene / TrypLE, pellet aspiration. Transport and spin are on the machine today.

NeXCell R automated incubator

Status: As built at IRENA

Waken Tech NR-series CO₂ incubator with sliding plate stage, HEPA Class 5, RS-232 / Ethernet. Connected as the environmental sidecar.

Inline optics

Status: Acceptance test awaited

Whole-well brightfield plus fluorescence, robot coordinates, raw OME-TIFF. Highest-priority remaining module — Celigo-class.

Humanoid + NVIDIA Spark

Status: Proposal

Closed-room assistant for trolley moves and kit presentation. Onboard inference stays off the sterile gantry path.

Platform

One clone, one bank, then manufacture from a vial

Single-step multiplex gene editing on an iPSC, clonal sort, master cell bank, then manufacture from a vial — the same logic as the Prepaire iPSC platform schematic below. The schematic describes the commercial model for an allogeneic engineered bank. It is not a claim that any therapy exists or is approved.

  1. 01

    Single step multiplex gene editing

    Induced pluripotent stem cell (iPSC)

    Clonal sorting and selection

    × De-selected clones

  2. 02

    Single product candidate clone

    iPSC expansion and MCB creation

  3. 03

    Clonal Master Cell Bank (MCB)

    Manufactured starting from MCB Vial

  4. 04

    Stored Drug Inventory

  5. 05

    Treat thousands of patients on-demand

Prepaire iPSC platform schematic (allogeneic model), redrawn from the source figure. Patient-specific lines follow Route B instead; see Banks.

System specification

Connected hardware as installed at IRENA, September 2026.

ResearchStatus: Installed hardware, outside this app
SiteIRENA BSL-3 · Masdar, Abu Dhabi
EnclosureISO-style glass isolator, HEPA supply, CCTV
Vessels6-well, ULA 96, V-bottom 96, T25 / T75
IncubatorNeXCell R NR28/48 class · 37 °C ±0.5 · 5% CO₂
EnvironmentTemp, CO₂, optional O₂, ultrasonic RH
CommunicationsRS-232 / RS-485, Ethernet, CellOS LAM
IdentityBarcode + electronic batch genealogy
Release postureResearch use. Not a clinical release system.

Run the operating system

Open Command, compose a cell programme, and watch the SAT-7 feeder-free cycle on the simulated deck.

Open command
CellOS · Prepaire Labs · IRENA BSL-3, MasdarStatus: Gantry link simulatedInc 36.94 °C / 5.06% CO₂ / 94% RH (simulated)Research use · not a clinical release system

Demonstration copy