SU-000001

Sysmex UD-10

Read-only, byte-exact copy of the U-WAM ASTM result session; each result names the module that measured it (UD-10), so VERA attributes it to this asset. Images only through a Sysmex-documented export. VERA never answers a query or downloads an order.
ActiveTo set up on site
Laboratory room lined with enclosed instruments
Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.
Release findings remain open.
The asset workbook records no room for this asset.

Extraction playbook

  1. Record the module serial, software version, U-WAM version, reagent and QC lots.
  2. Obtain the Sysmex U-WAM host-interface specification R315168 and freeze the message profile.
  3. Capture a read-only, byte-exact copy of the U-WAM ASTM result session (frames, checksums, ENQ/ACK/EOT); VERA never answers a query or downloads an order.
  4. Attribute each result to this module through R-14 and map host codes, units and grades through the signed Sysmex host-code table.
  5. Apply identity, QC, carryover, amended-result and flag-only gates before release.

Connection to VERA

Awaiting connection

KERNEL is this analyser's host. Awaiting a channel on VERA's listener.

Instrument identity

Manufacturer
Sysmex
Model
UD-10
Serial
•••44
Facility
Unrecorded
Evidence role
analytical
Software mode
EXTERNAL VENDOR RUNTIME

Evidence contract

Native evidence
ASTM result records (RAW and MAINFORMAT), reviewed particle classifications, particle images when exportable, audit events
Open derivatives
ASTM E1394 host result stream (read-only copy), FHIR DiagnosticReport/Observation projection
Vendor software
UD-10 system software, Sysmex U-WAM (LIS2-A2, R315168)
KG eligibility
Disabled pending dual site activation

Acceptance tests

KERNEL simulator frames and the golden U-WAM fixtures yield every Check marker of this module with the right LOINC, unit and module.
Awaited
Physical module inventory and serial match the register and the U-WAM configuration.
Awaited
QC and carryover failures block release.
Awaited

Primary sources

Site activation attestations

No site approval is recorded in your session. Patient run creation remains disabled.
VERA refuses an approval of this instrument today, as it would at the lab:
  • Its connection to VERA is not qualified yet: its connection is still to be set up on site.
  • The Directory records no room for the UD-10.
  • The version of its control software (U-WAM) is not recorded yet.
  • Sysmex's specification for its connection is not yet in hand.
A revocation can still be recorded. Try an approval to see the rule bite.