SRA-CK-000001

Cobot 10Kg

Use a supported authenticated interface or signed export and retain the complete execution trace before deriving sample lineage.
ActiveVendor interface needed
Laboratory room lined with enclosed instruments
Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.

Extraction playbook

  1. Record asset, control software, firmware, method checksum, operator, deck/layout, and consumable lots.
  2. Capture worklist identity, barcode events, executed actions, errors, interventions, and timestamps.
  3. Hash and seal method and execution records before interpretation.
  4. Reconcile input sample identity to every output container or plate position.
  5. Block downstream evidence when trace, identity, method, or process-control checks fail.

Connection to VERA

Reads its log files

VERA reads a Fairino cobot log from this machine when it is handed over as a file, and maps each line to a step with its sample and plate.

Robot and liquid-handler logs

Instrument identity

Manufacturer
Fairino
Model
Fairino FR10
Serial
••••••••01
Facility
Sample Reciving Area
Evidence role
automation
Software mode
EXTERNAL VENDOR RUNTIME

Evidence contract

Native evidence
method/worklist, barcode events, executed steps, volumes or positions, errors, audit log
Open derivatives
sample lineage JSON, process-event JSON
Vendor software
Installed control software and method packages must be inventoried
KG eligibility
Disabled pending dual site activation

Acceptance tests

Positive, negative, duplicate, and mismatch fixtures produce the approved lineage states.
Awaited
Manual interventions and errors remain visible and force the configured review.
Awaited
Method or software changes invalidate the current validation decision.
Awaited

Site activation attestations

No site approval is recorded in your session. Patient run creation remains disabled.
VERA refuses an approval of this instrument today, as it would at the lab:
  • Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
  • Still to do at the lab: obtain the vendor interface or export specification and exact installed software, firmware, and method versions.
  • It is not an analyser, so it cannot start a patient run.
A revocation can still be recorded. Try an approval to see the rule bite.
A pseudonymous identity, such as qa.officer.1 or director.1: letters, digits and dots, never a name. The quality manager and the laboratory director must be two different people.

Demonstration copy