LPR-HR-000002

Haier refrigerator, 2–8 °C

Use a supported read-only API or export. Preserve source timezone, sensor identity, calibration, alarms, and missing-data intervals.
ActiveVendor interface needed
Laboratory room lined with enclosed instruments
Your sessionEmpty. What you run, approve or register on these pages: kept in this server's memory for 30 minutes after your last action, seen only by you, never written to disk.

Extraction playbook

  1. Record controller, probe, serial, location, software/firmware, timezone, and calibration identity.
  2. Export readings, alarms, set-point changes, and missing-data intervals at the highest supported resolution.
  3. Hash and seal each source export before time normalisation.
  4. Convert timestamps to UTC while preserving source timestamps and offsets.
  5. Associate excursions with affected sample and reagent custody windows only through explicit time/location joins.

Connection to VERA

Reads its readings files

VERA reads this fridge's readings when they are handed over as a file and checks them against 2–8 °C.

Storage readings

Instrument identity

Manufacturer
Qingdao Haier Biomedical Co., Ltd
Model
HYC-610
Serial
BEDSP SEUD0 OCJL1 F0012
Facility
Library Preparation Room
Evidence role
environmental
Software mode
EXTERNAL VENDOR RUNTIME

Evidence contract

Native evidence
timestamped sensor readings, alarms, set-point changes, calibration records
Open derivatives
signed environmental event JSON, CSV time series
Vendor software
Installed controller/logger software must be inventoried
KG eligibility
Disabled pending dual site activation

Acceptance tests

Clock drift, timezone, calibration, and missing-data checks pass.
Awaited
Alarm events and source readings reconcile for a controlled excursion fixture.
Awaited
Environmental data cannot silently change an analytical value; it creates a release gate or qualifier.
Awaited

Site activation attestations

No site approval is recorded in your session. Patient run creation remains disabled.
VERA refuses an approval of this instrument today, as it would at the lab:
  • Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
  • Still to do at the lab: obtain the exact controller or logger interface and installed firmware or software inventory.
  • It is not an analyser, so it cannot start a patient run.
A revocation can still be recorded. Try an approval to see the rule bite.
A pseudonymous identity, such as qa.officer.1 or director.1: letters, digits and dots, never a name. The quality manager and the laboratory director must be two different people.

Demonstration copy