  1. Record the analyser serial, installed system software, middleware, firmware, Ionify assay menu, method versions and host-interface profile.
  2. Obtain Roche's current host-interface and any supported raw or chromatogram export specifications, including licensing and retention constraints.
  3. Capture and hash original result messages, flags, calibration, QC, reagent-lot, internal-standard, maintenance and audit records before normalisation.
  4. If native LC-MS evidence is exportable, seal it unchanged and qualify any open conversion separately against the vendor record.
  5. Normalise analyte identity, method, units, precision, flags and reference intervals without replacing the source result.
  6. Run assay-specific analytical and interface validation before accepting patient evidence.

Connection to VERA

Built, switched off

VERA's listener is built and switched off for this analyser (ports 21015 and 21016): it reads a copy of the analyser's link once IT routes one to it on site. KERNEL stays its host; VERA only reads.

Instrument identity

Manufacturer
Roche
Model
cobas i601
Serial
••••••••03
Facility
Clinical Pathology
Evidence role
analytical
Software mode
EXTERNAL VENDOR RUNTIME

Evidence contract

Native evidence
native LC-MS acquisition or chromatogram evidence when Roche exposes a supported export, original assay result records and flags, calibration and QC records, Ionify reagent, calibrator, internal-standard, method and lot identities, instrument logs and audit events
Open derivatives
original host result stream, FHIR DiagnosticReport/Observation projection, mzML only if a Roche-supported and locally validated conversion path exists
Vendor software
cobas i 601 system software, Ionify assay and result software, Roche middleware or host interface
KG eligibility
Disabled pending dual site activation

Acceptance tests

Golden host-message fixtures preserve analyte, value, units, precision, flags, method, lot and amendment semantics.
Awaited
Calibrator, internal-standard and QC failures prevent patient-evidence release.
Awaited
Any native-data conversion is byte-traceable to its source and meets the approved concordance contract.
Awaited
The validated reportable assay menu, measuring ranges and reference-interval sources are explicit.
Awaited

Primary sources

Site activation attestations

No site approval is recorded in your session. Patient run creation remains disabled.
VERA refuses an approval of this instrument today, as it would at the lab:
  • Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
  • Still to do at the lab: obtain the exact installed software, host-interface and supported native-data export package from Roche.
  • Still to do at the lab: confirm the installed Ionify assay menu and complete assay-specific analytical validation.
A revocation can still be recorded. Try an approval to see the rule bite.
A pseudonymous identity, such as qa.officer.1 or director.1: letters, digits and dots, never a name. The quality manager and the laboratory director must be two different people.

Demonstration copy