CP-CPMS-000001
Cobas Pro Mass Spec
Use the supported Roche host or middleware interface and seal every original result, flag, calibration and QC event. Capture native chromatographic or spectral evidence only through a documented Roche export; do not infer that an open raw-data path exists.
ActiveVendor interface needed

Extraction playbook
- Record the analyser serial, installed system software, middleware, firmware, Ionify assay menu, method versions and host-interface profile.
- Obtain Roche's current host-interface and any supported raw or chromatogram export specifications, including licensing and retention constraints.
- Capture and hash original result messages, flags, calibration, QC, reagent-lot, internal-standard, maintenance and audit records before normalisation.
- If native LC-MS evidence is exportable, seal it unchanged and qualify any open conversion separately against the vendor record.
- Normalise analyte identity, method, units, precision, flags and reference intervals without replacing the source result.
- Run assay-specific analytical and interface validation before accepting patient evidence.
Connection to VERA™
Built, switched offVERA's listener is built and switched off for this analyser (ports 21015 and 21016): it reads a copy of the analyser's link once IT routes one to it on site. KERNEL stays its host; VERA only reads.
Instrument identity
- Manufacturer
- Roche
- Model
- cobas i601
- Serial
- ••••••••03
- Facility
- Clinical Pathology
- Evidence role
- analytical
- Software mode
- EXTERNAL VENDOR RUNTIME
Evidence contract
- Native evidence
- native LC-MS acquisition or chromatogram evidence when Roche exposes a supported export, original assay result records and flags, calibration and QC records, Ionify reagent, calibrator, internal-standard, method and lot identities, instrument logs and audit events
- Open derivatives
- original host result stream, FHIR DiagnosticReport/Observation projection, mzML only if a Roche-supported and locally validated conversion path exists
- Vendor software
- cobas i 601 system software, Ionify assay and result software, Roche middleware or host interface
- KG eligibility
- Disabled pending dual site activation
Acceptance tests
Golden host-message fixtures preserve analyte, value, units, precision, flags, method, lot and amendment semantics.
AwaitedCalibrator, internal-standard and QC failures prevent patient-evidence release.
AwaitedAny native-data conversion is byte-traceable to its source and meets the approved concordance contract.
AwaitedThe validated reportable assay menu, measuring ranges and reference-interval sources are explicit.
AwaitedPrimary sources
Site activation attestations
No site approval is recorded in your session. Patient run creation remains disabled.
VERA refuses an approval of this instrument today, as it would at the lab:
- Its connection to VERA is not qualified yet: the maker's interface package for its connection is not yet in hand.
- Still to do at the lab: obtain the exact installed software, host-interface and supported native-data export package from Roche.
- Still to do at the lab: confirm the installed Ionify assay menu and complete assay-specific analytical validation.
A revocation can still be recorded. Try an approval to see the rule bite.