Storage readings

Fridge, freezer and room readings, checked by VERA against their limits

Reagents and samples are kept in fridges and freezers, and the rooms have their own limits. A logger reads each one every few minutes. VERA reads those readings, checks each against the device's limits, raises an alarm when a reading stays outside them too long, and notices when the logger went quiet. Only real readings make the storage record: readings from a simulation are shown and checked, and never counted.
  1. 1 · Reads each readingDevice, time, value and unit. No unit, no reading: VERA never guesses between °C and °F.
  2. 2 · Checks the limitsA short spell outside the limits is an alert; one that lasts longer than the device's delay is an alarm. A silent logger is a gap.
  3. 3 · Keeps the storage recordFrom real readings only. A simulated reading carries its marker everywhere and never counts as a storage record.

Read a day of readings

Sample readings

Made by VERA for this page from a fixed formula, as invented loggers would send them for one day. No sensor took them.

  • Sample Reagent fridge, one day
    Haier HYC-610 in Reagent Storage, a reading every 5 minutes from logger LG-SYN-0001
  • Sample −20 freezer, one day
    Haier DW-25L262 in the BSL-3 stem cell room, a reading every 10 minutes from logger LG-SYN-0002
  • Sample Room sensor, one day
    Govee H5075 in Reagent Storage, temperature and humidity every 15 minutes, as its app exports them

Or a readings file on this computer

A table (.csv or .tsv) with a time column and a value and unit, or a temperature or humidity column with its unit in the header, or JSON readings; up to 8 MB. Read in this browser; nothing is uploaded.

Humidity limits (% RH): now 30–60% RH
Temperature limits (°C): now 18–25 °C

What VERA found

  • As it should be192 readings from 2 sensor series (RS-STH-000001).
  • As it should beEvery real reading is within its limits, with no gap.

Smart Thermo-Hygrometer · Humidity

RS-STH-000001 · Reagent Storage · Room sensor · 96 real

Storage record: 96 readings from 00:00 GST to 23:45 GST, 12 Nov 2026, every one within 30–60% RH.

Latest: 44.5% RH at 23:45 GST, 12 Nov 2026.

00:00 GST30–60% RH read23:45 GST
ReadingsInside the limitsOutside the limits

Smart Thermo-Hygrometer · Temperature

RS-STH-000001 · Reagent Storage · Room sensor · 96 real

Storage record: 96 readings from 00:00 GST to 23:45 GST, 12 Nov 2026, every one within 18–25 °C.

Latest: 20.9 °C at 23:45 GST, 12 Nov 2026.

00:00 GST18–25 °C read23:45 GST
ReadingsInside the limitsOutside the limits

Demonstration copy