Robot and liquid-handler logs

What each robot did to each tube, read by VERA from its log

The robots and liquid handlers at IRENA move tubes, pipette blood and DNA into plates, and write down every step in a log. VERA reads such a log line by line: when, which machine, what it did, whether it went wrong, and which tube and plate each line names. It follows every tube to the plate and well it went to, and says plainly where a step failed or a tube could not be identified.
  1. 1 · One step per lineHamilton trace files, Fairino and Epson robot logs, and MGI liquid-handler tables, read into the same kind of step.
  2. 2 · Follows each tubeA dispense names only where the liquid went, so VERA carries the tube each pipetting channel took up to its next dispense.
  3. 3 · Holds what went wrongAn error holds the samples it touched; a run that never ended, or a well filled from a tube nobody could identify, holds too.

Read a log

Sample logs

Made by VERA for this page in each machine's shape: invented tubes in IRENA's label format, invented plates and racks. No machine wrote them.

  • Sample Hamilton STARlet EasyBlood, blood fractionation
    Three tubes split into plasma and buffy coat plates
  • Sample Hamilton Microlab STAR, DNA normalisation
    DNA from three wells moved into a library plate
  • Sample Fairino FR5 cobot, pass box to centrifuge
    Three tubes scanned, picked and placed in the centrifuge rack
  • Sample Epson C8 robot, tubes to a library plate
    Three tubes moved from a rack to plate wells
  • Sample MGISP-960, DNA extraction
    Three samples transferred to an extraction plate, lysis buffer added

Or a log file on this computer

A Hamilton .trc trace, a Fairino or Epson log, or an MGI table (.csv or .tsv), up to 8 MB. Read in this browser; nothing is uploaded.

What VERA read

Hamilton VENUS trace file from Hamilton Microlab STAR (LPR-HMS-000001), Library Preparation Room. From 09:12 GST to 09:14 GST, 12 Nov 2026. Every step is read, and nothing went wrong.

Lines
7
Step events
11
Samples
3
Plates and racks
2
Errors
0
Warnings
0
  • As it should beRead as a Hamilton VENUS trace file: 7 lines, 11 step events.
  • As it should beNo step reported an error.
  • As it should beEvery step that started also ended.
  • As it should be3 samples named; 3 followed to a plate or rack position.
  • Noted4 step events name no sample and no plate (moves, tips, start and end): kept as steps of the run.

Each tube, followed

Each sample and where it went
TubeWent toStepsFirstLastErrors
IRN261112011PLT-261112-04 A1209:13 GST09:14 GSTNone
IRN261112012PLT-261112-04 B1209:13 GST09:14 GSTNone
IRN261112013PLT-261112-04 C1209:13 GST09:14 GSTNone

Plates and racks

Plates and racks the log names
Plate or rackTubes in itWells and positionsSteps
PLT-261112-03IRN261112011, IRN261112012, IRN261112013A1, B1, C14
PLT-261112-04IRN261112011, IRN261112012, IRN261112013A1, B1, C14

Every step

Step events
LineTimeStepTubesPlate or rackWellVolumeDetails
109:12 GSTExecute method (start)NoneNoneNoneNoneMethod file DNA_Normalisation_96.hsl (synthetic)
209:13 GSTLoad Carrier (end)NonePLT-261112-03, PLT-261112-04NoneNoneCarrier PLT_CAR_L5_0002: plate PLT-261112-03 (DNA), plate PLT-261112-04 (library)
309:13 GSTTip Pick Up (end)NoneNoneNoneNonechannel 1: TIPS_50_0001, A1; channel 2: TIPS_50_0001, B1; channel 3: TIPS_50_0001, C1
409:13 GSTAspirate (end)IRN261112011PLT-261112-03A120 µLchannel 1: plate PLT-261112-03, well A1, sample IRN261112011, 20 uL
409:13 GSTAspirate (end)IRN261112012PLT-261112-03B120 µLchannel 2: plate PLT-261112-03, well B1, sample IRN261112012, 20 uL
409:13 GSTAspirate (end)IRN261112013PLT-261112-03C120 µLchannel 3: plate PLT-261112-03, well C1, sample IRN261112013, 20 uL
509:14 GSTDispense (end)IRN261112011 taken up at line 4PLT-261112-04A120 µLchannel 1: plate PLT-261112-04, well A1, 20 uL
509:14 GSTDispense (end)IRN261112012 taken up at line 4PLT-261112-04B120 µLchannel 2: plate PLT-261112-04, well B1, 20 uL
509:14 GSTDispense (end)IRN261112013 taken up at line 4PLT-261112-04C120 µLchannel 3: plate PLT-261112-04, well C1, 20 uL
609:14 GSTTip Eject (end)NoneNoneNoneNonechannel 1, 2, 3: waste
709:14 GSTExecute method (end)NoneNoneNoneNone3 samples normalised

Demonstration copy